Panasonic XE9WKUA Full Line Catalog - Page 51

Remote Controllers - Residential and, Light Commercial PAC

Page 51 highlights

Remote Controllers - Residential and Light Commercial (PAC) SERIES WIRELESS WIRED S26PK2U6 S26PT2U6 S36PT2U6 S42PT2U6 S26PF2U6 S36PF2U6 (Included) OPTION A: *CZ-RTC5A High Spec Control With filter countdown For Title 24, ECONAVI Ready CZ-RWST2U Controller with Receiver (Option) OPTION B: CZ-RTC4 Timer Control ECOVAVI Ready CZ-RWSK1U Controller CZ-RWSC3 Receiver (Option) CZ-CENSC1 ECONAVI Sensor (Option) S26PU2U6 S36PU2U6 S42PU2U6 *High-Spec Wired Remote Controller, Stylish, Easy to Use and ECONAVI Ready CZ-RWSU3U Controller with Receiver (Option) Option C: CZ-RE2C2 with on/off, temp and mode control Multiple Control Setting Functions for More Energy Savings Temperature Auto Run: Even if you change the temperature setting, it automatically returns to the original setting after a set time. You can set temperature auto return time in 10-minute intervals within a 4-hour period. Temperature Setting Range: Both Max. and Min. temperature settings can be limited. Doing this helps reduce power consumption due to over cooling or heating. Setting is possible in the Cooling, Heating and Dry modes. Auto Shutoff: Air conditioning operation can be programmed to stop its operation automatically after a set time, so you don't have to worry about forgetting to switch the unit off. Even if you manually switch the unit back on after it has stopped, the program will continue to activate and continue to switch off the operation after a set time. Menu items • Basic instructions • FLAP • Individual louver control (Lock individual flap only for 4-way cassette MU type) • ON/ OFF timer • Weekly timer • Filter information • Outing function • Quiet operation mode • Energy saving • Initial settings • Ventilation Energy Saving • Temperature auto return • Temperature setting range • Auto shutoff • Schedule peak cut • Repeat off timer • ECONAVI on/ off Maintenance Function • Outdoor unit error data • Service Contact address • RC setting mode • Test Run • Sensor Information • Service check • Simple/ Detailed Settings • Auto address 2020 FULL LINE CATALOG 51

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64

2020 FULL LINE CATALOG
51
SERIES
WIRELESS
WIRED
S26PK2U6
S26PT2U6
S36PT2U6
S42PT2U6
S26PF2U6
S36PF2U6
S26PU2U6
S36PU2U6
S42PU2U6
Multiple Control Setting Functions for More Energy Savings
Temperature Auto Run:
Even if you change the temperature setting, it automatically returns to the original setting after a
set time. You can set temperature auto return time in 10-minute intervals within a 4-hour period.
Temperature Setting Range:
Both Max. and Min. temperature settings can be limited. Doing this helps reduce power
consumption due to over cooling or heating. Setting is possible in the Cooling, Heating and Dry modes.
Auto Shutoff:
Air conditioning operation can be programmed to stop its operation automatically after a set time, so you don’t
have to worry about forgetting to switch the unit off. Even if you manually switch the unit back on
after it has stopped, the
program will continue to activate and continue to switch off the operation after a set time.
*High-Spec Wired Remote Controller, Stylish, Easy to Use and ECONAVI Ready
(Included)
CZ-RWST2U
Controller with Receiver (Option)
CZ-RWSK1U
Controller
CZ-RWSC3
Receiver (Option)
CZ-RWSU3U
Controller with Receiver (Option)
OPTION A:
*CZ-RTC5A
High Spec Control
With filter countdown
For Title 24, ECONAVI Ready
OPTION B:
CZ-RTC4
Timer Control
ECOVAVI Ready
CZ-CENSC1
ECONAVI Sensor (Option)
Option C:
CZ-RE2C2
with on/off,
temp and mode control
Remote Controllers – Residential and
Light Commercial (PAC)
Maintenance Function
Outdoor unit error data
Service Contact address
RC setting mode
Test Run
Sensor Information
Service check
Simple/ Detailed Settings
Auto address
Energy Saving
Temperature auto return
Temperature setting range
Auto shutoff
Schedule peak cut
Repeat off timer
ECONAVI on/ off
Menu items
Basic instructions
FLAP
Individual louver control
(Lock individual flap only
for 4-way cassette MU type)
ON/ OFF timer
Weekly timer
Filter information
Outing function
Quiet operation mode
Energy saving
Initial settings
Ventilation