Panasonic XE9WKUA Full Line Catalog - Page 39

Connect 2 to 3 Indoor Units, Outdoor Unit

Page 39 highlights

-5°F Heat Operation 2-3 Zone (1.5 Ton) CU-3E19RBU-5 Cooling Capacity: 19,000 (6,100 - 24,800) Btu/hr. Heating Capacity: 26,000 (5,000 - 28,400) Btu/hr. SEER Non-Ducted 22.0 / Ducted 18.5 EER Non-Ducted 12.55 / Ducted 10.85 HSPF Non-Ducted 10.5 / Ducted 9.0 Min/Max capacity 15,300 - 30,600 Btu/hr. Wireless Controller (Included) Wired Remote Controller CZ-RD516C-1 (Optional) Connect 2 to 3 Indoor Units Wireless Controller (Included) Wired Controller with 32 ft cable CZ-RD52CU (Optional) CZ-BT20U CU-3E19RBU-5 (Non-Ducted) See Multi Zone Calculation and Selection Chart on pp. 42-43. Outdoor Unit MODEL NO. Performance Capacity Btu/h Air Circulation High CFM Number of Connectable Indoor Units SEER Non-Ducted / Ducted EER Non-Ducted / Ducted HSPF Non-Ducted / Ducted Electrical Rating Power Supply Running Ampere Power Input Maximum Fuse Size : MCA / MOCP V, Phase, Hz Non-Ducted / Ducted A W Amps Features Controls Fan Speeds Compressor Refrigerant / Amount Charged at Shipment Refrigerant Control Operation Sound Hi Refrigerant Tubing Connections Max. Allowable Tubing Length Refrigerant Tube Diameter Discharge (service value) Suction dB-A Type Ft. inch inch Adapter Required Dimensions & Weight Unit Dimensions H x W x D inch Net Weight Lbs. Cooling 19,000 (6,100~24,800) 1,447 7.4~6.7 / 8.5~7.7 1,510 (360~2,420) 50 Important: You must use refrigerant piping rated for R410a. See pages 57-60 for additional information. *Test Conditions based on AHRI 210/240 CU-2E18SBU-5 2-3 22.0 / 18.5 12.55 / 10.85 10.5 / 9.0 230V / 208V, 1PH, 60Hz 20/30 Microprocessor Variable Speed Twin Rotary, DC Motor, Inverter R-410A / 93.2 oz Electronic Expansion Valve Flare 164 per system (82 per indoor unit) 1/4" x 3 3/8" x 3 Indoor 12 and 18 Btu/hr. require 1 CZ-MA1P-US 31-5/16 x 34-15/32 x 14-3/6 159 Heating 26,000 (5,500~28,400) 1,634 10.1~9.1 / 12.3~11.1 2,060 (320~2,300) 52 2020 FULL LINE CATALOG 39

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64

2020 FULL LINE CATALOG
39
Zone (1.5 Ton)
2-3
Wireless
Controller
(Included)
Wired Remote
Controller
CZ-RD516C-1
(Optional)
Wireless
Controller
(Included)
Wired Controller
with 32 ft cable
CZ-RD52CU
(Optional)
CZ-BT20U
Connect 2 to 3 Indoor Units
(Non-Ducted)
See Multi Zone Calculation and Selection Chart on pp. 42-43.
Important:
You must use refrigerant piping rated for R410a. See pages 57-60 for additional information.
*Test Conditions based on AHRI 210/240
CU-3E19RBU-5
Cooling Capacity: 19,000 (6,100 - 24,800) Btu/hr.
Heating Capacity: 26,000 (5,000 - 28,400) Btu/hr.
SEER Non-Ducted 22.0
/ Ducted 18.5
EER
Non-Ducted 12.55 / Ducted 10.85
HSPF Non-Ducted 10.5
/ Ducted 9.0
Min/Max capacity 15,300 - 30,600 Btu/hr.
MODEL NO.
CU-2E18SBU-5
Performance
Cooling
Heating
Capacity
Btu/h
19,000 (6,100~24,800)
26,000 (5,500~28,400)
Air Circulation
High
CFM
1,447
1,634
Number of Connectable Indoor Units
2±3
SEER
Non±Ducted / Ducted
22.0 / 18.5
EER
Non±Ducted / Ducted
12.55 / 10.85
HSPF
Non±Ducted / Ducted
10.5 / 9.0
Electrical Rating
Power Supply
V, Phase, Hz
230V / 208V, 1PH, 60Hz
Running Ampere
Non±Ducted / Ducted
A
7.4~6.7 / 8.5~7.7
10.1~9.1 / 12.3~11.1
Power Input
W
1,510 (360~2,420)
2,060 (320~2,300)
Maximum Fuse Size : MCA / MOCP
Amps
20/30
Features
Controls
Microprocessor
Fan Speeds
Variable Speed
Compressor
Twin Rotary, DC Motor, Inverter
Refrigerant / Amount Charged at Shipment
R±410A / 93.2 oz
Refrigerant Control
Electronic Expansion Valve
Operation Sound
Hi
dB±A
50
52
Refrigerant Tubing Connections
Type
Flare
Max. Allowable Tubing Length
Ft.
164 per system (82 per indoor unit)
Refrigerant Tube Diameter
(service value)
Discharge
inch
1/4” x 3
Suction
inch
3/8” x 3
Adapter Required
Indoor 12 and 18 Btu/hr. require 1 CZ±MA1P±US
Dimensions & Weight
Unit Dimensions
H x W x D
inch
31±5/16 x 34±15/32 x 14±3/6
Net Weight
Lbs.
159
Outdoor Unit
-5°F Heat Operation
CU-3E19RBU-5