Pentax ZX-M ZX-M Manual - Page 35
Ii 1111
View all Pentax ZX-M manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 35 highlights
3 II tJ Ii1111 • A n 16 11 8 5.64 250 F-- .70 FF gootpdal 4. 3. Turn either the shutter dial or lens aperture ring until a dot is displayed in the center of the bar graph at the right side of the viewfinder. Note: When a lens other than an F or FA lens is used, no approximate aperture indication will appear in the viewfinder. • When the dots are displayed to the [ + side on the bar graph, it indicates overexposure and when the dots are displayed to the [ - ] side, it indicates underexposure. Moving one dot on the bar graph indicates 0.5 step (0.5EV). However, when under or over exposure is set beyond + 3 or 3 steps (3EV), [ + ] or [ - ] indicator will blink. • In flash photography, when you use the flash sync shutter speed of 1/100 second or a non-dedicated external flash unit, set the shutter dial to the [ 100 ] (1/100 of second) position. Note: When a lens with no lens information contacts is used, the center-weighted metering mode is automatically set. When using a SMC Pentax 50mm f/1.2 lens with the lens aperture ring set other than the A position, the center weighted metering mode will be set instead of the multi-segment metering mode. As the exposure will come out 1 stop over, set the lens aperture ring to [ A ], or adjust the exposure deliberately to 1 stop under. SNOIIVEI3dO O33NVAaV