Pioneer DEH-P300 Service Manual - Page 30
Waveforms
View all Pioneer DEH-P300 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 30 highlights
DEH-P300,P3000,P200 - Waveforms Note:1. The encircled numbers denote measuring pointes in the circuit diagram. 2. Reference voltage REFO:2.5V 1 RFI 0.5V/div. 0.5µs/div. Normal mode: play 1 CH1: RFI 2 CH2: MIRR 1V/div. 0.5ms/div. 5V/div. Test mode: Tracking open 1 CH1: RFI 1V/div. 2 CH2: MIRR 5V/div. 0.5ms/div. Normal mode: The defect part passes 800µm REFO → REFO → REFO → REFO → REFO → 3 CH1: FD 4 CH2: FO+ 0.5V/div. 0.2s/div. 2V/div. Test mode: No disc, Focus close 3 CH1: FD 0.5V/div. 0.2s/div. 5 CH2: FOK 2V/div. Normal mode: Focus close 6 CH1: FE 7 CH2: XSI 0.5V/div. 1ms/div. 2V/div. Normal mode: Focus close REFO → REFO → REFO → REFO → REFO → REFO → GND → 8 CH1: TE 9 CH2: TD 0.5V/div. 0.5ms/div. 0.5V/div. 8 CH1: TE 9 CH2: TD 0.5V/div. 0.5ms/div. 0.5V/div. 8 CH1: TE 9 CH2: TD 0.5V/div. 5ms/div. 0.5V/div. Test mode: 32 tracks jump (REV) Test mode: Single jump (REV) Test mode: 100 tracks jump (REV) REFO → REFO → REFO → REFO → REFO → REFO → 6 CH1: FE 3 CH2: FD 0.1V/div. 20ms/div. 3 CH1: FD 0.2V/div. 0 CH2: MD 0.5V/div. 0.5s/div. 3 CH1: FD 1V/div. 0 CH2: MD 0.5V/div. 0.5s/div. 1V/div. Normal mode: Play Normal mode: Focus close (12cm) Normal mode: Focus close (8cm) REFO → REFO → 30 REFO → REFO → REFO → REFO →