Pioneer DEH-P300 Service Manual - Page 67

Display of Operational Status CPOINT during Setup

Page 67 highlights

DEH-P300,P3000,P200 (4) Display of Operational Status (CPOINT) during Setup Status No. Contents 00 CD+5V ON process in progress. 01 Servo LSI initialization (1/3) in progress. 02 Servo LSI CRAM initialization in progress. 03 Servo LSI initialization (2/3) in progress. 04 Offset adjustment (1/3) in progress. 05 Offset adjustment (2/3) in progress. 06 Offset adjustment (3/3) in progress. 07 FZD adjustment in progress. 08 Servo LSI initialization (3/3) in progress. 10 Carriage move to home position started. 11 Carriage move to home position started. 12 Carriage is moving toward inner diameter. 13 Carriage is moving toward outer diameter. 14 Carriage outer kick in progress. 15 Carriage outer diameter feed (1 second) in progress. 20 Servo close started. 21 Pre-processing for focus search started. 22 Spindle rotation and focus search started. 23 Waiting for focus close (XSI=Low). 24 Standing by after focus close is over. 25 Focus search preprocessing is in progress while setup protection is turned on. 26 Focus search preprocessing is in progress while focus recovery is turned on. 27 Wait time after focus close is set up. 28 Standing by after focus close is over. 29 Setup (1/2) before T balance adjustment is started. 30 Setup (2/2) before T balance adjustment is started. 31 T balance adjustment started. 32 T balance adjustment (1/2). 33 T balance adjustment (2/2). 34 Waiting for spindle rotation to end. Spindle rough servo. 35 Standing by after spindle rough servo is over. 36 RF AGC started. 37 RF AGC started. 38 RF AGC ending process in progress. 39 Tracking close in progress. 40 Standing by after tracking is closed. Carriage closing in progress. 41 Focus/tracking AGC started. 42 Focus AGC started. 43 Focus AGC in progress. 44 Tracking AGC in progress. 45 Standing by after focus/tracking AGC are over. 46 Spindle processes applicable servo. 47 Check for servo close is started. 48 Check of LOCK pin started. 49 RF AGC started. 50 RF AGC in progress. 51 Standing by after RF AGC is over. Protective action None None None None None None None None None None None Specified 10 seconds has been passed or failure on home switch. Specified 10 seconds has been passed or failure on home switch. None None None None None Specified focus search time has been passed. Specified focus search time has been passed. None None Off focus. Off focus. Off focus. Off focus. Off focus. Off focus. Off focus. Off focus. Off focus. Off focus. Off focus. Off focus. Off focus. Off focus. Off focus. Off focus. Off focus. Off focus. Off focus. Off focus. Off focus. Off focus or spindle not locked. Off focus. Off focus. Off focus. 67

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83

67
DEH-P300,P3000,P200
(4) Display of Operational Status (CPOINT) during Setup
Status No.
Contents
Protective action
00
CD
+
5V ON process in progress.
None
01
Servo LSI initialization (1/3) in progress.
None
02
Servo LSI CRAM initialization in progress.
None
03
Servo LSI initialization (2/3) in progress.
None
04
Offset adjustment (1/3) in progress.
None
05
Offset adjustment (2/3) in progress.
None
06
Offset adjustment (3/3) in progress.
None
07
FZD adjustment in progress.
None
08
Servo LSI initialization (3/3) in progress.
None
10
Carriage move to home position started.
None
11
Carriage move to home position started.
None
12
Carriage is moving toward inner diameter.
Specified 10 seconds has been passed or failure
on home switch.
13
Carriage is moving toward outer diameter.
Specified 10 seconds has been passed or failure
on home switch.
14
Carriage outer kick in progress.
None
15
Carriage outer diameter feed (1 second) in progress.
None
20
Servo close started.
None
21
Pre-processing for focus search started.
None
22
Spindle rotation and focus search started.
None
23
Waiting for focus close (XSI
=
Low).
Specified focus search time has been passed.
24
Standing by after focus close is over.
Specified focus search time has been passed.
25
Focus search preprocessing is in
None
progress while setup protection is turned on.
26
Focus search preprocessing is in
None
progress while focus recovery is turned on.
27
Wait time after focus close is set up.
Off focus.
28
Standing by after focus close is over.
Off focus.
29
Setup (1/2) before T balance adjustment is started.
Off focus.
30
Setup (2/2) before T balance adjustment is started.
Off focus.
31
T balance adjustment started.
Off focus.
32
T balance adjustment (1/2).
Off focus.
33
T balance adjustment (2/2).
Off focus.
34
Waiting for spindle rotation to end.
Off focus.
Spindle rough servo.
35
Standing by after spindle rough servo is over.
Off focus.
36
RF AGC started.
Off focus.
37
RF AGC started.
Off focus.
38
RF AGC ending process in progress.
Off focus.
39
Tracking close in progress.
Off focus.
40
Standing by after tracking is closed.
Off focus.
Carriage closing in progress.
41
Focus/tracking AGC started.
Off focus.
42
Focus AGC started.
Off focus.
43
Focus AGC in progress.
Off focus.
44
Tracking AGC in progress.
Off focus.
45
Standing by after focus/tracking AGC are over.
Off focus.
46
Spindle processes applicable servo.
Off focus.
47
Check for servo close is started.
Off focus.
48
Check of LOCK pin started.
Off focus or spindle not locked.
49
RF AGC started.
Off focus.
50
RF AGC in progress.
Off focus.
51
Standing by after RF AGC is over.
Off focus.