Rane ZR1 CP64S Installation Manual - Page 11
PR2 and ZR1 Remotes
View all Rane ZR1 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 11 highlights
CP64S COMMERCIAL PROCESSOR PR2 and ZR1 Remotes The CP64S supports wired remotes for Page Assign, Zone Level and Zone Source selection. Wire lengths of up to 1000 feet are possible. A brief list of suitable wire types is provided in the WIRE TYPES section on the next page. The PR2 remote provides Page Zone Assign for Page 1 and Page 2 inputs and is usually located at the Page source. If your application requires one of the two PAGE ASSIGN switches to control both Page 1 and Page 2 Assign, simply wire all Page 1 and Page 2 ports in parallel. You may leave the knob off the unused control and cover it with one of the hole plugs provided in the kit. If your installation requires Page 1 and Page 2 remote control at two different locations, only three wires are required for each PR2 remote (Z1, Z2 & GND). As above, you may leave the knob off the unused control and cover it with a hole plug. The ZR1 remote provides Zone Level and Source Selection, allowing local control from inside the Zone. Two ZR1 remotes may be used (only use one in each Zone). If only one of the two controls is used, you may cover the unused control with one of the hole plugs provided in the kit. If you require one ZR1 remote to control both Zones, simply wire the ports in parallel. This may be done with Program Select only, Level only or both. If only one of the two controls is wired in parallel, the other is still available for a second remote. When paralleling one remote across multiple CP64S's, all three control pins must be wired, including the shields. Keep the power cable unplugged to the CP64S until all connections are made. It is important to ensure that the CP64S Remote Ports are not subjected to sustained voltages outside the range of 0 to 5 volts DC or high levels of static. Inputs are protected, however, caution is the better part of... you know. It is a good idea to install the wiring, connect it to the remote assemblies and then make the final connections at the CP64S. Do not short Vr1 or Vr2 pins to ground. These pins are current limited, however, excess heat is generated in the 5 volt supply if a short occurs. Never subject the Vr1 or Vr2 pins to voltages above 5 volts. ZR1 Zone / Level L2 L3 L1 P PROGRAM SELECT 46 2 8 0 10 LEVEL PR2 Paging Assign Z1 Z2 OFF BOTH PAGE 1 ASSIGN Z1 Z2 OFF BOTH PAGE 2 ASSIGN Decora plate (not included) Decora plate (not included) J1A D1 1 D0 2 S1B 9 10 8 7 6 GND S1A 4 5 3 2 1 3 GND 3 CW GND Vc 4 2 R1 2KRD 1 Vr 5 5 POS TERM ZONE REMOTE (ZR 1) PAGE 1 J1A Z2 5 Z1 4 GND Z1 PAGE 2 Z2 3 GND 2 1 5 POS TERM S2B 9 10 8 7 6 GND S2A 4 5 3 2 1 S1A GND 4 5 3 2 1 S1B GND 9 10 8 7 6 GND PAGE REMOTE (PR 2) 11