Rane ZR1 CP64S Installation Manual - Page 4
Quick Start - remote control
View all Rane ZR1 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 4 highlights
CP64S COMMERCIAL PROCESSOR PAGING ZONE ASSIGN LEVEL PAGE 1 PAGE 2 ZONE 1 ZONE 2 12 12 4 6 4 6 RMT 1&2 RMT 1&2 ACTIVE 0 10 0 10 ACTIVE PROGRAM INPUT LEVELS ZONE 1 ZONE 2 LINE 1 4 6 0 10 LINE 2 4 6 0 10 LINE 3 4 6 0 10 PRIORITY 4 6 DUCKER PROGRAM DEPTH SELECT L2 L3 L1 P RMT LEVEL 4 6 DUCKER PROGRAM DEPTH SELECT L2 L3 L1 P RMT LEVEL 4 6 OFF ON 0 10 OFF ON 10 SIG OL 10 SIG OL ZONE 1 ZONE 2 + 12 • 6 • 0 • 6 • 12 40 100 250 630 1.6k 4k 10k 40 100 250 630 1.6k 4k 10k CP64S COMMERCIAL PROCESSOR POWER Quick Start If you were the type that cheated on school book reports by just skimming through the reading assignments, then this page is for you! It gives you not quite enough information to really know what you're doing. But, if you follow the recommended set up procedure, you should get at least a "B." Keep the amplifiers and the CP64S turned off until all connections are made. INTERNAL SETTINGS Access to the following internal controls requires removal of the top cover. All internal settings should be complete before you install the CP64S, before you attach the power cable. The factory default settings work for many applications. However, you may need to change one or more for your system. See "Internal Adjustments" on page 9 if you want to change these defaults: • Each Page Input has a 15 volt Phantom Power switch. The default is off. • The Page Priority switch assigns priority override to Page 1, Page 2 or NO (none). The default is Page 1. If a Page has priority, it overrides the non-priority Page in the Zone(s) it is assigned. The NO priority setting allows the Pagers to mix. • Each Page Input may sum with the Program Pre- or PostVCA. When set to Pre-VCA, Zone Level, EQ and Limiter circuits act upon the Page. When summed Post-VCA, the Page is not influenced by Zone Level, EQ or Limiter circuits. The default is Post-VCA. • The Zone 1 Stereo/Mono switch default is Stereo. • There are two internal trim controls for the Program Priority detector. The Program Priority Threshold trim has a range of -∞ to -35 dBu with a default of -50 dBu. The Program Priority Release Time has a range of 2 to 20 seconds. The default is 12 seconds. PAGE INPUTS Connect Page Inputs to the Euroblock on the rear panel and select the appropriate MIC or LINE switch position for each. First, set the gain with the Page TRIM control, then set the Page DETECT THRESHOLD and finally the Page Zone LEVEL. PR2 REMOTE If you use the optional PR2 Remote (sold separately), wire it to the rear RMT ZONE ASSIGN Euroblock as shown in "PR2" on page 11. If you require remote control but do not wish to use a PR2, any simple switch closure to GND will work. These inputs are also TTL compatible (0 to 5 VDC). PROGRAM INPUTS Connect Program sources to the RCA PROGRAM INPUTS. If you have a priority program, like a jukebox, connect it to the PRIORITY Input. The Program PRIORITY ASSIGN ZONE switch assigns priority override to Off, Zone 1, Zone 2, or Both. In the Zone(s) that it is assigned, the priority program is automatically selected when signal is detected. EXPAND OUTPUTS Wire the EXPAND OUTPUT Euroblock for each Zone as required. These are cross-coupled line drivers and may be used balanced or unbalanced. Each Expand Output can be Page-only, Program-only or its Zone signal. The Zone source will not include the Page if the Page is summed Post-VCA. Page is always available from the Page source. ZONE OUTPUTS Wire the two ZONE OUT Euroblocks as required. These are cross-coupled line drivers and may be used balanced or unbalanced. Set the LIMIT threshold as required. ZR1 REMOTE You may use one or two optional ZR1 Remotes (sold separately) with each CP64S. If you use the ZR1, wire it to the rear REMOTES Euroblock as shown on "ZR1" on page 11. If a ZR1 remote is not ideal, any simple switch closure to ground will work for the D0 and D1 pins. These pins are TTL compatible (0 to 5 VDC). The logic is inverse Gray Code. Any ground referenced 5 volt DC control may be used as the input to V1 or V2. Do not ground the Vr1 or Vr2 pins. SETUP ADVICE The CP64S is very versatile. While this makes a large number of system applications possible, it also results in complexity. For this reason, it is important to use an organized approach for setup and calibration. Please read and follow the "Recommended Calibration Procedure" on page 13. This will avoid problems and reduce the need to increase our collective phone bills. 4WEAR PARTS: This product contains no wear parts.