Rane ZR1 CP64S Installation Manual - Page 8

Rear Panel

Page 8 highlights

CP64S COMMERCIAL PROCESSOR Rear Panel CP64S COMMERCIAL AUDIO 100-240 V EQUIPMENT 24TJ 50/60 Hz 12 WATTS R Z2 PGM Z2 LEVEL REMOTES WIRING MIN MAX Vr Vc OUTPUTS Z2 EXPAND Z2 MONO ALL AUDIO AND REMOTES ARE CLASS 2 WIRING ZONE 2 ZONE 1 EXPAND OUT EXPAND OUT ZONE PAGE ZONE PAGE RANE CORP. MADE IN U.S.A. ACN 001 345 482 Z1 PGM D1 D0 Z1 LEVEL Vr Vc 2 PGM 1 PGM Z1 EXPAND Z1 RIGHT Z1 LEFT +- +- +- PROGRAM INPUTS LIMITER PRIORITY ZONE 1 ZONE 2 ASSIGN ZONE L L +8 +8 off 1 2 -20 +20 -20 +20 R R 1&2 PRIORITY 3 2 1 REMOTE PAGE REMOTE 1 INPUT 1 ZONE ASSIGN WIRING Z1 Z2 PAGING INPUTS PAGE 2 TRIM PAGE 1 TRIM PAGE 2 PAGE 1 DETECT THRESHOLD REMOTE 2 INPUT 2 Z2 Z1 +- +30 +60 OL +30 +60 MIC LINE MIC LINE q 07 6 54 3 8 91 2 1 PAGING INPUT Euroblock connectors may be operated balanced or unbalanced. See "CP64S Connections" on page 10. If either page mic needs phantom power, see "Internal Adjustments" on page 9. 2 PAGE 1 and PAGE 2 INPUT MIC / LINE switches select 30 dB Input Pads when set to LINE. Phantom Power (if enabled) is disabled when LINE is selected. If either page mic needs phantom power, see "Internal Adjustments" on page 9. PAGE 1 and PAGE 2 INPUT TRIM controls adjust Page Input preamplifier gain to match the microphone/source in use, not to set the page level in the Zones. The range is 30 dB to 60 dB. PAGING INPUTS OL indicator lights when either of the Page Input preamplifiers comes within 3 dB of clipping, assisting the setting of these trims. Page 1 is set at the factory for priority over Page 2. If you want to change this, see "Internal Adjustments" on page 9. 3 Four PROGRAM INPUTS are provided. Three are non-priority Inputs. The fourth is a Program PRIORITY Input. When signal is present at the PRIORITY Input, it is automatically selected as the Input source in the Zone(s) it is assigned with the Program PRIORITY ASSIGN ZONE switch. 4 PRIORITY ASSIGN ZONE switch determines in which Zone(s) the automatic priority override is enabled. Off (none), Zone 1, Zone 2 or Both are the possible settings. If you do not intend to use the Priority Input as an automatic override Input, do not assign it with this switch. Use the Zone PROGRAM SELECT switch on the front panel. 5 LIMITER threshold controls set the maximum output level for each Zone. These circuits are true voltage limiters with a ratio of 15:1. The threshold range is -20 dBu to +20 dBu. 6 OUTPUTS feature balanced cross-coupled line drivers with a Euroblock connector for each Zone. Zone 1 is stereo. Zone 2 is mono, and both Expand outputs are mono. When operating cross-coupled line drivers unbalanced, it is essential to ground the (-) pin. See "CP64S Connections" on page 10. 7 ZONE EXPAND OUT switches assign Page-only, Program-only or Zone 1 or Zone 2 as the source for each Expand Output. 8 DETECT THRESHOLD sets the Paging input signal level required to gate a Page on and light the front panel ACTIVE indicator. The range is -∞ (on) to +4 dBu. 9 REMOTE PAGE ZONE ASSIGN port provides connection to the PR2 wired remote. The PR2 remote is used for Zone assignment of the Page Inputs at another location. Follow the wiring for "PR2" on page 11. 0 REMOTES ports provides connection for two optional ZR1 wired remotes. Each ZR1 remote provides remote control of Zone Level and Zone Program Selection. Follow the wiring for "ZR1" on page 11. q Universal Voltage Input: via a miniature IEC 60320 C6 appliance inlet. This mates with an IEC 60320 C5 line cord (USA domestic). Do not lift the ground connection! 8

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26

8
CP64S
COMMERCIAL PROCESSOR
Rear Panel
1
PAGING INPUT
Euroblock connectors may be operated balanced or unbalanced. See "CP64S Connections" on page 10. If
either page mic needs phantom power, see "Internal Adjustments" on page 9.
2
PAGE 1 and PAGE 2 INPUT MIC / LINE
switches select 30 dB Input Pads when set to LINE.
Phantom Power (if enabled) is
disabled when LINE is selected.
If either page mic needs phantom power, see "Internal Adjustments" on page 9.
PAGE 1 and PAGE 2 INPUT TRIM
controls adjust Page Input preamplifier gain to match the microphone/source in use,
not
to
set the page level in the Zones. °e range is 30 dB to 60 dB.
PAGING INPUTS OL
indicator lights when either of the Page Input preamplifiers comes within 3 dB of clipping, assisting the
setting of these trims.
Page 1 is set at the factory for priority over Page 2. If you want to change this, see "Internal Adjustments" on page 9.
3
Four
PROGRAM INPUTS
are provided. °ree are non-priority Inputs. °e fourth is a Program PRIORITY Input. When signal
is present at the PRIORITY Input, it is
automatically
selected as the Input source in the Zone(s) it is assigned with the Program
PRIORITY ASSIGN ZONE switch.
4
PRIORITY ASSIGN ZONE
switch determines in which Zone(s) the automatic priority override is enabled.
Off
(none),
Zone 1
,
Zone 2
or
Both
are the possible settings. If you do not intend to use the Priority Input as an
automatic override
Input, do
not
assign
it with this switch. Use the Zone PROGRAM SELECT switch on the front panel.
5
LIMITER
threshold controls set the maximum output level for each Zone. °ese circuits are true voltage limiters with a ratio of
15:1. °e threshold range is -20 dBu to +20 dBu.
6
OUTPUTS
feature balanced cross-coupled line drivers with a Euroblock connector for each Zone. Zone 1 is stereo. Zone 2 is
mono, and both Expand outputs are mono.
When operating cross-coupled line drivers unbalanced, it is
essential
to ground the (–)
pin.
See "CP64S Connections" on page 10.
7
ZONE EXPAND OUT
switches assign
Page
-only,
Program
-only or
Zone 1 or Zone 2
as the source for each Expand Output.
8
DETECT THRESHOLD
sets the Paging input signal level required to gate a Page
on
and light the front panel ACTIVE
indicator. °e range is -∞ (on) to +4 dBu.
9
REMOTE PAGE ZONE ASSIGN
port provides connection to the PR2 wired remote. °e PR2 remote is used for Zone assign-
ment of the Page Inputs at another location. Follow the wiring for "PR2" on page 11.
0
REMOTES
ports provides connection for two optional ZR1 wired remotes. Each ZR1 remote provides remote control of Zone
Level and Zone Program Selection. Follow the wiring for "ZR1" on page 11.
q
Universal Voltage Input:
via a miniature IEC 60320 C6 appliance inlet. °is mates with an IEC 60320 C5 line cord (USA
domestic). Do
not
lift the ground connection!
PRIORITY
ASSIGN
ZONE
ZONE
1
PAGE
+30
+60
1&2
PRIORITY
3
2
1
RANE CORP. MADE IN U.S.A.
OL
Z2
Z1
Z1
Z2
+
+
+
+
D1
D0
Vr
Vc
Vr
Vc
1
2
DETECT THRESHOLD
REMOTE PAGE
ZONE ASSIGN WIRING
PAGE 2
PAGE 1
LIMITER
WIRING
ZONE 1
ZONE 2
PAGE
1
TRIM
PAGE
2
TRIM
CP64S
+8
+8
PAGING INPUTS
R
L
R
L
+30
+60
MIC
LINE
–20
+20
–20
+20
REMOTES
OUTPUTS
MIN
MAX
PROGRAM INPUTS
ZONE
2
EXPAND OUT
ZONE
1
EXPAND OUT
ZONE
2
Z2
PGM
Z2
EXPAND
Z2
MONO
REMOTE
1
INPUT
1
REMOTE
2
INPUT
2
Z1
RIGHT
Z1
EXPAND
Z1
LEFT
Z2
LEVEL
Z1
PGM
Z1
LEVEL
ACN 001 345 482
MIC
LINE
100-240 V
50/60 Hz 12 WATTS
COMMERCIAL AUDIO
EQUIPMENT 24TJ
R
PGM
PGM
PAGE
off
ALL AUDIO AND
REMOTES ARE
CLASS 2 WIRING
q
0
6
1
9
4
7
2
8
5
3