Samsung NX60A6711SS/AA Installation Guide - Page 12
Installation requirements
View all Samsung NX60A6711SS/AA manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 12 highlights
Installation requirements Location requirements Clearances and dimensions BEFORE YOU BEGIN to install this appliance, refer to the following information, dimensions, and clearances. Do not locate the range where it may be subject to strong drafts. Provide adequate clearances between the range and adjacent combustible surfaces. These dimensions must be met for safe use of the range. The location of the electrical outlet and gas piping may be adjusted to meet the following dimensions and clearances. CAUTION This range has been designed to comply with the maximum allowable wood cabinet temperature of 194 °F (90 °C). Make sure the wall covering, countertops, and cabinets around the range can withstand the heat (up to 194 °F [90 °C]) generated by the range. If not, discoloration, delamination, or melting may occur. Side Clearance Above Cooking Surface to Wall 4 in (10.2 cm) Minimum from top of cooktop to cabinets 30 in (76.2 cm) 30 in (76.2 cm) 6 in (15.2 cm) 18 in (45.7 cm) 13 in (33 cm) Overhead Cabinet Depth 36 in (91.4 cm) 24 in (61 cm) Lower Cabinet Depth 0 in (0 cm) Clearance Below Cooking Top and at Rear and Sides of Range 24.2 in (61.5 cm) 0 in (0 cm) CAUTION Do not grab the knobs or handle when you install. CAUTION DO NOT install the oven so that the door is flush with the cabinet. For OTR above Gas Stove, please follow local GAS CODE. Installation requirements 12 English Install_NX60A6_DG68-01337A-00_EN+MES+CFR.indb 12 2020-12-30 10:56:11