When COMP does not operate

Page 59 highlights

Diagnostics 13-3) When COMP does not operate Pre-Check "Check out the COMP with the Forced Operation selected" 1. If it does not pass 5 min after a desired Temp reached,COMP does not operate. 2. During Defrost,COMP does not operate. 3. With the disconnected F-Sensor or R-Sensor,COMP does not operate because low temperature is detected. Start Is Forced Operation on? YES Is the MICOM #22 output "HIGH"(5V)? YES Is the IC70 #12 "LOW"(0.7V)? YES Is COMP RELAY normal? YES Is the contact of CONNECTOR CN70 contact normal NO Does COMP ASS'Y Function normally? YES Check wire assembly/connection NO Run Forced Operation NO Soldering checkout/ Change MICOM or PCB NO Change or repair IC04/ NO Change PCB YES Check RELAY / Change PCB - Reference • Load terminal Measure method. Insert Connector completely / Check its connection NO Change/repair COMP 59

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80

59
Diagnostics
“Check out the COMP with the Forced Operation selected”
1. If it does not pass 5 min after a desired Temp reached,COMP does not operate.
2. During Defrost,COMP does not operate.
3. With the disconnected F-Sensor or R-Sensor,COMP does not operate because low
temperature is detected.
Pre-Check
13-3) When COMP does not operate
NO
NO
NO
NO
YES
NO
Run Forced Operation
Is Forced Operation on?
Is the
MICOM #22 output
"HIGH"(5V)?
Is the IC70 #12
"LOW"(0.7V)?
Is COMP RELAY normal?
Is the contact
of CONNECTOR CN70
contact normal
Does
COMP ASS'Y Function
normally?
Start
YES
Soldering checkout/
Change MICOM or PCB
Change or repair IC04/
Change PCB
YES
Check RELAY /
Change PCB
- Reference
• Load terminal Measure
method.
YES
Insert Connector completely /
Check its connection
YES
Change/repair COMP
NO
YES
Check wire assembly/connection