Samsung RS257BABB Service Guide - Page 51

If the panel PCB is not working normally

Page 51 highlights

Diagnostics 11-6) If the panel PCB is not working normally: 1) When the entire Panel PCB does not light up or a portion of LCD does not light up Start � Refer to Circuit Diagram in this manual or on the back of the product. � When the Panel button does not work Is the connector of Fre Upp Hinge Cover inserted correctly? YES Is Main PCB Connector (CN50) inserted correctly? YES I s Door Panel PCB Connect or inserted correctly YES Does it light up normally after Panel PCB is replaced? NO NO NO YES Insert Connector correctly, Repair contact error Insert Main PCB Connector correctly Insert Connector correctly, Repair contact error NO 1. F-Door Wire Check -Wi re Cut/Short 2. F-CABI Wire Check -Wire Cut/Short 3. Main PCB Panel Lamp Circuit -Short/Open Check 2) When the Panel PCB button does not work - When the problem is not corrected with the above checking methods Defective Panel PCB Is Lock lamp on? YES NO Kept being pressed Is a same button kept being pressed down? Check after unlocking the system YES Work after Doesn 't it work even after disassembly PCB mechanical parts are disassembled? YES Does it light up properly after changing Panel PCB? YES Reassemble PCB Ass'y/ Ease the button Reassemble PCB Ass'y/ Ease the button NO Defective Panel PCB 1. F-Door Wire Check - Wire Cut/Short 2. F-CABI Wire Check - Wire Cut/Short 3. Main PCB Panel Comm/Power Supply Circuit -Short/Open Check 51

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66

51
Diagnostics
11-6) If the panel PCB is not working normally:
1) When the entire Panel PCB does not light up or a portion of LCD does not light up
2) When the Panel PCB button does not work
- When the problem is not corrected with the above checking methods
Is the connector of Fre Upp
Hinge Cover inserted correctly?
Start
Insert Connector correctly,
Repair contact error
Is Main PCB Connector (CN50)
inserted correctly?
Insert Main PCB
Connector correctly
I s Door Panel PCB Connect or
inserted correctly
Insert Connector correctly,
Repair contact error
1. F-Door Wire Check –Wi re Cut/Short
2. F-CABI Wire Check –Wire Cut/Short
3. Main PCB Panel Lamp Circuit -Short/Open Check
1. F-Door Wire Check – Wire Cut/Short
2. F-CABI Wire Check – Wire Cut/Short
3. Main PCB Panel Comm/Power Supply Circuit -Short/Open Check
NO
NO
YES
YES
NO
Defective Panel PCB
YES
YES
Does it light up normally after
Panel PCB is replaced?
NO
NO
Check after unlocking the system
YES
Is Lock lamp on?
YES
Reassemble PCB Ass’y/
Ease the button
Kept being
pressed
Is a same button kept being
pressed down?
YES
Reassemble PCB Ass’y/
Ease the button
Work after
disassembly
Doesn ’t it work even after
PCB mechanical parts are
disassembled?
NO
Defective Panel PCB
YES
Does it light up properly
after changing Panel PCB?
²
Refer to Circuit Diagram
in this manual or on the
back of the product.
²
When the Panel button
does not work