Sanyo 12KS71 Installation Instructions - Page 3

General - installation

Page 3 highlights

05-424 KS0971-1271 12/13/05 1:27 PM Page 3 1. General This booklet briefly outlines where and how to install the air conditioning system. Please read over the entire set of instructions for the indoor and outdoor units and make sure all accessory parts listed are with the system before beginning. 1-1. Tools Required for Installation (not supplied) 1. Standard screwdriver 2. Phillips head screwdriver 3. Knife or wire stripper 4. Tape measure 5. Carpenter's level 6. Sabre saw or key hole saw 7. Hacksaw 8. Core bits 9. Hammer 10. Drill 11. Tube cutter 12. Tube flaring tool 13. Torque wrench 14. Adjustable wrench 15. Reamer (for deburring) 1-2. Accessories Supplied with Unit Table 1 Parts Remote control unit Figure Q'ty 1 Parts Tapping screw Figure Truss-head Phillips 5/32 ¥ 5/8" (4¥16 mm) Q'ty 10 Parts Hex wrench* Figure Q'ty 1 Remote control unit holder 1 Rawl plug 8 Clamp 1 AAA alkaline battery Drain hose 2 adapter *Packed in the outdoor unit. 1 Air clean filter 2 Cushion rubber* 4 1-3. Optional Copper Tubing Kit Copper tubing for connecting the outdoor unit to the indoor unit is available in kits which contain the narrow and wide tubing, fittings and insulation. Consult your nearest sales outlet or A/C workshop. 1-4. Type of Copper Tube and Insulation Material If you wish to purchase these materials separately from a local source, you will need: 1. Deoxidized annealed copper tube for refrigerant tubing as detailed in Table 2. Cut each tube to the appropriate lengths 1' to 1'4" (30 cm to 40 cm) to dampen vibration between units. 2. Foamed polyethylene insulation for the specified copper tubes as required to precise length of tubing. Wall thickness of the insulation should be not less than 5/16" (8 mm). 3. Use insulated copper wire for field wiring. Wire size varies with the total length of wiring. Refer to 3-6. Wiring Instructions for details. CAUTION Check local electrical codes and regulations before obtaining wire. Also, check any specified instructions or limitations. Table 2 Model KS0971/1271 Narrow Tube Outer Dia. Thickness 1/4" (6.35 mm) 0.0314" (0.8 mm) Wide Tube Outer Dia. Thickness 3/8" (9.52 mm) 0.0314" (0.8 mm) 3

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

3
1.
General
This booklet briefly outlines where and how to install the
air conditioning system. Please read over the entire set
of instructions for the indoor and outdoor units and make
sure all accessory parts listed are with the system before
beginning.
1-1.
Tools Required for Installation (not supplied)
1.
Standard screwdriver
2.
Phillips head screwdriver
3.
Knife or wire stripper
4.
Tape measure
5.
Carpenter’s level
6.
Sabre saw or key hole saw
7.
Hacksaw
8.
Core bits
9.
Hammer
10.
Drill
11.
Tube cutter
12.
Tube flaring tool
13.
Torque wrench
14.
Adjustable wrench
15.
Reamer (for deburring)
1-2.
Accessories Supplied with Unit
Table 1
1-3.
Optional Copper Tubing Kit
Copper tubing for connecting the outdoor unit to the
indoor unit is available in kits which contain the narrow
and wide tubing, fittings and insulation. Consult your
nearest sales outlet or A/C workshop.
1-4.
Type of Copper Tube and Insulation Material
If you wish to purchase these materials separately from
a local source, you will need:
1.
Deoxidized annealed copper tube for refrigerant tub-
ing as detailed in Table 2.
Cut each tube to the appropriate lengths 1' to 1'4"
(30 cm to 40 cm) to dampen vibration between units.
Table 2
2.
Foamed polyethylene insulation for the specified
copper tubes as required to precise length of tubing.
Wall thickness of the insulation should be not less
than 5/16" (8 mm).
3.
Use insulated copper wire for field wiring. Wire size
varies with the total length of wiring. Refer to 3-6.
Wiring Instructions for details.
Part
s
Fi
g
ure
Q’ty
Part
s
Fi
g
ure
Q’ty
1
1
2
Rawl pl
ug
Tappi
ng s
crew
Hex wre
n
ch
*
Tr
uss
-head
Phillip
s
5
/
3
2
¥
5
/
8
" (4
¥
16 mm)
1
2
AAA alkali
n
e
battery
10
8
1
Part
s
Fi
g
ure
Q’ty
Remote
co
n
trol
un
it
Remote co
n
trol
un
it holder
Air clea
n
filter
1
*
Packed i
n
the o
u
tdoor
un
it.
Clamp
Drai
n
ho
s
e
adapter
C
us
hio
n
r
u
bber
*
4
CAUTION
Check local electrical codes
and regulations before
obtaining wire. Also, check
any specified instructions or
limitations.
Model
Narrow Tube
Wide Tube
Outer Dia.
Thickness
Outer Dia.
Thickness
KS0971/1271
1/4" (6.35 mm)
0.0314" (0.8 mm)
3/8" (9.52 mm)
0.0314" (0.8 mm)
05-424 KS0971-1271
12/13/05
1:27 PM
Page 3