Sanyo HECSR1000K Service Manual - Page 20

Replacement of transfomer, Unscrew fixing screws to remove the folder

Page 20 highlights

Replacement Procedure (21) Replacement of transfomer 1. Unscrew three fixing screws to remove the transformer cover. Photo.28 Screws Trans cover Photo.29 2. Unscrew fixing screws to remove the folder and pull out a connector. 3. Unscrew fixing screws to remove the transformer. Photo.30 Screws Transfomer Photo.30 HEC-DR21 (TAIWAN) Oct./2002 Printed in Japan - 20 - SANYO Electric Co.,Ltd Osaka, Japan

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20

Photo.29
Photo.30
Trans cover
Screws
Transfomer
Screws
(
21
) Replacement of transfomer
1. Unscrew three fixing screws to remove the
transformer cover.
Photo.28
2. Unscrew fixing screws to remove the folder
and pull out a connector.
3. Unscrew fixing screws to remove the
transformer.
Photo.30
-
20
-
SANYO
Electric Co.,Ltd
Osaka, Japan
Replacement Procedure
HEC-DR21
(TAIWAN)
Oct./2002 Printed in Japan