Operation Requirements
UPC - 086483078644
View all Sanyo PLC-XD2200 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 10 highlights
PLC-XD2200 / 2600 Basic Serial Command Specifications 6.4. Operation Requirements 1) When the projector's status is any of below, Functional Execution Commands are limited. Projector Status In Standby Countdown in process Cooling Down in process Cooling Down due to Abnormal Temperature Abnormal Temperature Status Abnormal Power Status Power Save / Cooling Down in process Power Save Status Input search On1/On2 setting Available Functional Execution Commands C00 POWER ON C00 POWER ON → Countdown is terminated C01 POWER OFF C02 POWER OFF → Countdown is terminated NONE (No Execution) NONE (No Execution) NONE (No Execution) NONE (No Execution) NONE (No Execution) C00 POWER ON C01 POWER OFF Although transmit Input source commands, Input search does not operate. Note) When the status is as above, even if the projector receives other commands, it returns [ACK] [CR]. 2) When Eco mode is selected in Standby mode of Setting menu and projector is in Standby, Functional Execution Commands are invalid. 9/23