Sanyo PLC-XD2200 RS232C Basic - Page 22
[CR], 04 [CR], 21 [CR]
UPC - 086483078644
View all Sanyo PLC-XD2200 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 22 highlights
PLC-XD2200 / 2600 Basic Serial Command Specifications information of temperature anomaly is canceled and normal operation is executed. "24" [CR] Status: Processing Power Save / Cooling Down Power management function in Setting menu works and the status goes to Power Save / Cooling Down. During this time, Functional Execution Commands are invalid (not executed). This status moves to Power Save at set hours after the operation of Cooling Down. Status No signal Response "00" Power Save / Cooling Down "24" Power Save "04" "04" [CR] 5 minutes with no signal After about 90 sec. Status: Power Save This shows that it moves to Power Save status by Power management function in Setting menu. "21" [CR] Status: Cooling Down in process after turned off due to lamp failure When a projector is turned off because of lamp failure, it automatically starts Cooling Down operation, in which the projector returns "21" [CR]. "81" CR Status: Standby after Cooling Down due to lamp failure This value is returned when Cooling Down operation due to lamp failure has been completed and the status has been moved to Standby. The status is kept until the next operation starts. 21/23