PLC-XD2200 / 2600 Basic Serial Command Specifications 7.5.Input Mode Read Command Command "CR1" [CR] Detail Get the selected Input No. Acceptable "%1" [CR] "1" = Computer 1 is selected Response %1 "2" = Computer 2 is selected "3" = Video is selected Unacceptable "?" [CR] 7.6.Lamp Time Read Command Command "CR3" [CR] Detail Get the total lamp running hours (Not actual lamp used hour, but Eco mode corresponding value). Acceptable "%1" [CR] Response %1 Shows the time period with 5 digits numbers. Example "00410"[CR] shows 410 hours Unacceptable "?" [CR] 7.7.Setting Read Command Command "CR4" [CR] Detail Get screen setting status such as Ceiling / Rear. Acceptable "%1" [CR] "11"[CR] = Normal Screen Setting "10"[CR] = Picture is top/bottom reversed. Response %1 (Status: Rear Ceiling ON) "01"[CR] = Picture is left/right reversed. (Status: Rear ON) "00"[CR] = Picture is top/bottom and left/right reversed. (Status: Ceiling ON) Unacceptable "?" [CR] 7.8.Temp Read Command Command "CR6" [CR] Detail Get the temperature data inside the projector. With some temperature sensors installed in the projector, it is possible to get all the temperature at once. Acceptable "%1_%2_%3" [CR] %1 Temperature of sensor 1 %2 Temperature of sensor 2 %3 Temperature of sensor 3 Temperature data is shown as "00.0". When the temperature goes down to -, the first character %1 becomes "-" instead of a space, like "-05.5" [CR]. Response %2 When no temperature data can be returned due to hardware %3 problems, the first character becomes "E" like"E00.0" [CR]. When several temperature sensors are equipped, Responses are returned continuously. "_31.5 _ _35.2 _ _33.4"[CR] The first data is sensor 1, then one space, and the data of sensor 2 follows. Unacceptable " "[CR] 22/23

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

PLC-XD2200 / 2600
Basic Serial Command Specifications
22/23
7.5. Input Mode Read Command
Command
“CR1” [CR]
Detail
Get the selected Input No.
Response
Acceptable
“%1” [CR]
%1
”1” = Computer 1 is selected
”2” = Computer 2 is selected
“3” = Video is selected
Unacceptable
“?” [CR]
7.6. Lamp Time Read Command
Command
“CR3” [CR]
Detail
Get the total lamp running hours (Not actual lamp used hour, but Eco mode
corresponding value).
Response
Acceptable
“%1” [CR]
%1
Shows the time period with 5 digits numbers.
Example
“00410”[CR]
・・・・
shows 410 hours
Unacceptable
“?” [CR]
7.7. Setting Read Command
Command
“CR4” [CR]
Detail
Get screen setting status such as Ceiling / Rear.
Response
Acceptable
“%1” [CR]
%1
“11”[CR] = Normal Screen Setting
“10”[CR] = Picture is top/bottom reversed.
(Status: Rear
Ceiling ON)
“01”[CR] = Picture is left/right reversed. (Status: Rear ON)
“00”[CR] = Picture is top/bottom and left/right reversed.
(Status: Ceiling ON
)
Unacceptable
“?” [CR]
7.8. Temp Read Command
Command
“CR6” [CR]
Detail
Get the temperature data inside the projector.
With some temperature sensors installed in the projector, it is possible to get all
the temperature at once.
Response
Acceptable
“%1_%2_%3” [CR]
%1
%2
%3
%1
Temperature of sensor 1
%2
Temperature of sensor 2
%3
Temperature of sensor 3
Temperature data is shown as “00.0”.
When the temperature goes down to -, the first character
becomes “-” instead of a space, like “-05.5” [CR].
When no temperature data can be returned due to hardware
problems, the first character becomes “E” like”E00.0” [CR].
When several temperature sensors are equipped, Responses are
returned continuously.
“_31.5 _ _
35.2
_ _33.4”[CR]
The first data is sensor 1, then one space, and the data of sensor
2 follows.
Unacceptable
”[CR]