Seagate 600 SSD Seagate 600 SSD Product Manual - Page 11

Power Specifications

Page 11 highlights

2.7 POWER SPECIFICATIONS The drive receives DC power (+5V) through a native SATA power connector. See 2 on page 16. 2.7.1 Power consumption Power requirements for the drives are listed in the table on page 9. Typical power measurements are based on an average of drives tested, under nominal conditions, at 35°C ambient temperature. • Startup power Startup power is measured from the time of power-on to the time that the drive reaches operating condition and can process media access commands. • Peak operating mode During peak operating mode, the drive is tested in various read and write access patterns to simulate the worst-case power consumption. • Idle mode power Idle mode power is measured with the drive powered up and ready for media access commands, with no media access commands having been received from the host. • Standby mode During Standby mode, the drive accepts commands, but not be able to immediately access the media because the drive electronics are in a partial power-down mode. 2.7.2 DC power requirements Table 2 480GB DC power requirements Parameter Voltage Regulation Average Idle Current Average Sleep Current Maximum Start Current DC (Peak DC) AC (Peak AC) Peak Operating Current (random read): Typical DC Maximum DC Maximum DC (peak) Peak Operating Current (random write): Typical DC Maximum DC Maximum DC (peak) Peak Operating Current (sequential read): Typical DC Maximum DC Maximum DC (peak) Peak Operating Current (sequential write): Typical DC Maximum DC Maximum DC (peak) ST480HM000, ST480HM001 +5V +/- 5% 0.22 0.10 0.95 0.54 0.40 (6.0Gb) Power (watts) 1.10 0.50 0.32 1.59 0.33 1.63 0.90 4.50 0.40 2.02 0.46 2.31 1.44 7.20 0.44 2.18 0.45 2.20 1.02 5.10 0.52 2.61 0.60 2.99 1.50 7.50 *During periods of drive idle, some offline activity may occur according to the S.M.A.R.T. specification, which may increase power to operational levels. SEAGATE 600 SSD PRODUCT MANUAL, REV. B 7

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39

S
EAGATE
600 SSD P
RODUCT
M
ANUAL
, R
EV
. B
7
2.7
P
OWER SPECIFICATIONS
The drive receives DC power (+5V) through a native SATA power connector. See 2 on page
16.
2.7.1
Power consumption
Power requirements for the drives are listed in the table on page 9. Typical power measurements are based on an average
of drives tested, under nominal conditions, at 35°C ambient temperature.
Startup power
Startup power is measured from the time of power-on to the time that the drive reaches operating condition and can pro-
cess media access commands.
Peak operating mode
During peak operating mode, the drive is tested in various read and write access patterns to simulate the worst-case
power consumption.
Idle mode power
Idle mode power is measured with the drive powered up and ready for media access commands, with no media access
commands having been received from the host.
Standby mode
During Standby mode, the drive accepts commands, but not be able to immediately access the media because the drive
electronics are in a partial power-down mode.
2.7.2
DC power requirements
Table 2
480GB DC power requirements
Parameter
ST480HM000,
ST480HM001
(6.0Gb)
Voltage
+5V
Power
Regulation
+/- 5%
(watts)
Average Idle Current
0.22
1.10
Average Sleep Current
0.10
0.50
Maximum Start Current
0.95
DC (Peak DC)
0.54
AC (Peak AC)
0.40
Peak Operating Current (random read):
Typical DC
0.32
1.59
Maximum DC
0.33
1.63
Maximum DC (peak)
0.90
4.50
Peak Operating Current (random write):
Typical DC
0.40
2.02
Maximum DC
0.46
2.31
Maximum DC (peak)
1.44
7.20
Peak Operating Current (sequential read):
Typical DC
0.44
2.18
Maximum DC
0.45
2.20
Maximum DC (peak)
1.02
5.10
Peak Operating Current (sequential write):
Typical DC
0.52
2.61
Maximum DC
0.60
2.99
Maximum DC (peak)
1.50
7.50
*During periods of drive idle, some offline activity may occur according to the S.M.A.R.T. specification, which may increase power to operational levels
.