Seagate 600 SSD Seagate 600 SSD Product Manual - Page 28

Number of LBAs transferred per Read Multiple or Write Multiple.

Page 28 highlights

4.3.1 Identify Device command The Identify Device command (command code ECH) transfers information about the drive to the host following power up. The data is organized as a single 512-byte block of data, whose contents are shown in Table 8 on page 22. All reserved bits or words should be set to zero. Parameters listed with an "x" are drive-specific or vary with the state of the drive. see Sectoi n 2.0 on page 3 for default parameter settings. The following commands contain drive-specific features that may not be included in the Serial ATA specification. WORD 0 1 2 3 4-5 6 7-8 9 10-19 20-21 22 23-26 27-46 47 48 49 50 51 52 53 54 55 56 57-58 59 60-61 62 63 64 65 66 DESCRIPTION General configuration Number of logical cylinders (obsolete) 16,383 Specific configuration Number of logical heads (obsolete) 16 Retired Number of logical sectors per logical track (obsolete) 63 Reserved for CompactFlash Association Retired Serial number: (ATA ASCII string padded with spaces (20H)) Retired Obsolete Firmware revision (ATA ASCII string padded with spaces (20h)) Model number (ATA ASCII string padded with spaces (20h)) (Bits 7-0) Maximum number of logical sectors that shall be transferred per DRQ data block on READ/WRITE MULTIPLE commands. 16 Reserved for Trusted Computing feature set options Capabilities - Standby Timer, IORDY Support, etc Capabilities Continued PIO data transfer cycle timing option (Obsolete) Retired Words 54-58, 64-70 and 88 are valid Number of current logical cylinders (Obsolete) Number of current logical heads (Obsolete) Number of current logical sectors per logical track (Obsolete) Current capacity in sectors (Obsolete) Number of LBAs transferred per Read Multiple or Write Multiple. Sanitize Command Support Total number of user addressable logical sectors for 28-bit commands Note: The maximum value allowed in this field is: 0FFFFFFFh. If this field contains 0FFFFFFFh and the device has user addressable LBAs greater than or 137GB, then words 100..103 contain the total number of user addressable LBAs Obsolete Multiword DMA active and modes supported (see note following this table) Advanced PIO modes supported. SATA = 0003h Minimum Multiword DMA transfer cycle time per word (120ns) Recommended Multiword DMA transfer cycle time (120ns) VALUE 0040H 3FFFH C837H 0010H 0000H 003FH 0000H 0000H ASCII 0000H 0000H ASCII ASCII 8010H 4000H 2F00H 4000H 0000H 0000H 0006H 3FFFH 0010H 003FH FC10H 00FBH 9110H XXXXXXXXH 0000H 0007H 0003H 0078H 0078H SEAGATE 600 SSD PRODUCT MANUAL, REV. B 24

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39

S
EAGATE
600 SSD P
RODUCT
M
ANUAL
, R
EV
. B
24
4.3.1
Identify Device command
The Identify Device command (command code EC
H
) transfers information about the drive to the host following power up.
The data is organized as a single 512-byte block of data, whose contents are shown in Table 8 on page
22. All reserved bits
or words should be set to zero. Parameters listed with an “x” are drive-specific or vary with the state of the drive. see Secti
on
2.0 on page 3 for default parameter settings.
The following commands contain drive-specific features that may not be included in the Serial ATA specification.
W
ORD
D
ESCRIPTION
V
ALUE
0
General configuration
0040
H
1
Number of logical cylinders (obsolete) 16,383
3FFF
H
2
Specific configuration
C837
H
3
Number of logical heads (obsolete) 16
0010
H
4-5
Retired
0000
H
6
Number of logical sectors per logical track (obsolete) 63
003F
H
7–8
Reserved for CompactFlash Association
0000
H
9
Retired
0000
H
10–19
Serial number: (ATA ASCII string padded with spaces (20
H
))
ASCII
20-21
Retired
0000
H
22
Obsolete
0000
H
23–26
Firmware revision (ATA ASCII string padded with spaces (20h))
ASCII
27–46
Model number (ATA ASCII string padded with spaces (20h))
ASCII
47
(Bits 7-0) Maximum number of logical sectors that shall be transferred per DRQ data
block on READ/WRITE MULTIPLE commands.
16
8010
H
48
Reserved for Trusted Computing feature set options
4000
H
49
Capabilities – Standby Timer, IORDY Support, etc
2F00
H
50
Capabilities Continued
4000
H
51
PIO data transfer cycle timing option (Obsolete)
0000
H
52
Retired
0000
H
53
Words 54–58, 64–70 and 88 are valid
0006
H
54
Number of current logical cylinders (Obsolete)
3FFF
H
55
Number of current logical heads (Obsolete)
0010
H
56
Number of current logical sectors per logical track (Obsolete)
003F
H
57–58
Current capacity in sectors (Obsolete)
FC10
H
00FB
H
59
Number of LBAs transferred per Read Multiple or Write Multiple.
Sanitize Command
Support
9110
H
60–61
Total number of user addressable logical sectors for 28-bit commands
Note: The maxi-
mum value allowed in this field is:
0FFFFFFFh. If this field contains 0FFFFFFFh and the
device has user addressable LBAs greater than or 137GB,
then words 100..103 contain
the total number of user addressable LBAs
XXXXXXXX
H
62
Obsolete
0000
H
63
Multiword DMA active and modes supported
(see note following this table)
0007
H
64
Advanced PIO modes supported.
SATA = 0003h
0003
H
65
Minimum Multiword DMA transfer cycle time per word
(120ns)
0078
H
66
Recommended Multiword DMA transfer cycle time (120ns)
0078
H