Drive activity LED

Page 80 highlights

10.11 Drive activity LED The following table provides drive activity LED status. Table 25: Drive activity LED status Spindle status Command status LED status Spinning up with DC power applied N/A Spun down Start Unit Powered down by removal of DC N/A power Spun up Stop Unit Spun down No command activity Spun down Write/Read Buffer Spun down SCSI Bus Reset Spun down Test Unit Ready Spun up No command activity Spun up Write/Read Spun up SCSI Bus Reset Spun up Test Unit Ready Spun up Format with Immediate option on Spun up Format without Immediate Spun up Write Same Command in progress On until spinup is complete On while processing the command Off due to absence of power On while processing the command Off On while processing the command On while processing the reset On while processing the command Off On while processing the command On while processing the reset On while processing the command On while the command is initially processed LED toggles on/off on each cylinder boundary Toggles on/off 74 Cheetah 15K.5 SCSI Product Manual, Rev. J

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88

74
Cheetah 15K.5 SCSI Product Manual, Rev. J
10.11
Drive activity LED
The following table provides drive activity LED status.
Table 25:
Drive activity LED status
Spindle status
Command status
LED status
Spinning up with DC power applied
N/A
On until spinup is complete
Spun down
Start Unit
On while processing the command
Powered down by removal of DC
power
N/A
Off due to absence of power
Spun up
Stop Unit
On while processing the command
Spun down
No command activity
Off
Spun down
Write/Read Buffer
On while processing the command
Spun down
SCSI Bus Reset
On while processing the reset
Spun down
Test Unit Ready
On while processing the command
Spun up
No command activity
Off
Spun up
Write/Read
On while processing the command
Spun up
SCSI Bus Reset
On while processing the reset
Spun up
Test Unit Ready
On while processing the command
Spun up
Format with Immediate option on
On while the command is initially processed
Spun up
Format without Immediate
LED toggles on/off on each cylinder boundary
Spun up
Write Same Command in prog-
ress
Toggles on/off