Seagate ST9146853SS Savvio 15K.1 SAS Product Manual - Page 18
Start/stop time, Prefetch/multi-segmented cache control
View all Seagate ST9146853SS manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 18 highlights
4.2.2 Format command execution time ST973451SS ST936751SS Maximum (with verify) 52 minutes 26 minutes Maximum (without verify) 35 minutes 18 minutes Execution time measured from receipt of the last byte of the Command Descriptor Block (CDB) to the request for a Status Byte Transfer to the Initiator (excluding connect/disconnect). 4.2.3 General performance characteristics Sustained trasfer rate 79 to 112 Mbytes/sec SAS Interface maximum instantaneous transfer rate 300 Mbytes/sec* per port (dual port = 600 Mbytes/sec*) Logical block sizes 512 (default), 520, 524 and 528 Read/write consecutive sectors on a track Yes Flaw reallocation performance impact (for flaws reallocated at format time using the spare sectors per sparing zone reallocation scheme.) Negligible Average rotational latency 2.0 msec *Assumes no errors and no relocated logical blocks. Rate measured from the start of the first logical block transfer to or from the host. 4.3 Start/stop time The drive accepts the commands listed in the SAS Interface Manual less than 3 seconds after DC power has been applied. If the drive receives a NOTIFY (ENABLE SPINUP) primitive through either port and has not received a START STOP UNIT command with the START bit equal to 0, the drive becomes ready for normal operations within 20 seconds (excluding the error recovery procedure). If the drive receives a START STOP UNIT command with the START bit equal to 0 before receiving a NOTIFY (ENABLE SPINUP) primitive, the drive waits for a START STOP UNIT command with the START bit equal to 1. After receiving a START STOP UNIT command with the START bit equal to 1, the drive waits for a NOTIFY (ENABLE SPINUP) primitive. After receiving a NOTIFY (ENABLE SPINUP) primitive through either port, the drive becomes ready for normal operations within 20 seconds (excluding the error recovery procedure). If the drive receives a START STOP UNIT command with the START bit and IMMED bit equal to 1 and does not receive a NOTIFY (ENABLE SPINUP) primitive within 5 seconds, the drive fails the START STOP UNIT command. The START STOP UNIT command may be used to command the drive to stop the spindle. Stop time is 30 seconds (maximum) from removal of DC power. There is no power control switch on the drive. 4.4 Prefetch/multi-segmented cache control The drive provides a prefetch (read look-ahead) and multi-segmented cache control algorithms that in many cases can enhance system performance. Cache refers to the drive buffer storage space when it is used in cache operations. To select this feature, the host sends the Mode Select command with the proper values in the applicable bytes in page 08h. Prefetch and cache operations are independent features from the standpoint that each is enabled and disabled independently using the Mode Select command; however, in actual operation, the prefetch feature overlaps cache operation somewhat as described in sections 4.5.1 and 4.5.2. 12 Savvio 15K SAS Product Manual, Rev. C