Seagate ST9250412AS Momentus 7200 FDE.2 SATA Product Manual - Page 18

Environmental specifications

Page 18 highlights

2.10 Environmental specifications 2.10.1 Ambient temperature Ambient temperature is defined as the temperature of the environment immediately surrounding the drive. Actual drive case temperature should not exceed 65°C (149°F) within the operating ambient conditions. Above 1,000 feet (305 meters), the maximum temperature is derated linearly by 1°C every 1000 feet. Operating Nonoperating 0° to 60°C (32° to 140°F) -40° to 70°C (-40° to 158°F) 2.10.2 Temperature gradient Operating Nonoperating 20°C per hour (68°F per hour max), without condensation 35°C per hour (95°F per hour max), without condensation 2.10.3 Humidity 2.10.3.1 Relative humidity Operating Nonoperating 5% to 95% noncondensing (30% per hour max) 5% to 95% noncondensing (30% per hour max) 2.10.3.2 Wet bulb temperature Operating Nonoperating 37.7°C (99.8°F max) 40°C (104°F max) 2.10.4 Altitude Operating Nonoperating -304.8 m to 3,048 m (-1,000 ft to 10,000+ ft) -304.8 m to 12,192 m (-1,000 ft to 40,000+ ft) 12 Momentus 7200 FDE.2 SATA Product Manual, Rev. B

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60

12
Momentus 7200 FDE.2 SATA Product Manual, Rev. B
2.10
Environmental specifications
2.10.1
Ambient temperature
Ambient temperature is defined as the temperature of the environment immediately surrounding the drive.
Actual drive case temperature should not exceed
65°C (149°F) within the operating ambient conditions.
Above 1,000 feet (305 meters), the maximum temperature is derated linearly by 1°C every 1000 feet.
2.10.2
Temperature gradient
Operating
20°C per hour (68°F per hour max), without condensation
Nonoperating
35°C per hour (95°F per hour max), without condensation
2.10.3
Humidity
2.10.3.1
Relative humidity
Operating
5% to 95% noncondensing (30% per hour max)
Nonoperating
5% to 95% noncondensing (30% per hour max)
2.10.3.2
Wet bulb temperature
Operating
37.7°C (99.8°F max)
Nonoperating
40°C (104°F max)
2.10.4
Altitude
Operating
–304.8 m to 3,048 m (–1,000 ft to 10,000+ ft)
Nonoperating
–304.8 m to 12,192 m (–1,000 ft to 40,000+ ft)
Operating
0° to 60°C (32° to 140°F)
Nonoperating
–40° to 70°C (–40° to 158°F)