Test Electrostatic discharge Radiated RF immunity Electrical fast transient Surge immunity Conducted RF immunity Power Frequency H-field immunity Voltage dips, interrupts Description Performance level Contact, HCP, VCP: ± 4 kV; Air: ± 8 kV B 80 to 2,000 MHz, 10 V/m, A 80% AM with 1 kHz sine 900 MHz, 3 V/m, 50% pulse modulation @ 200 Hz ± 1 kV on AC mains, ± 0.5 kV on external I/O B ± 1 kV differential, ± 2 kV common, AC mains B 150 kHz to 80 MHz, 3 Vrms, 80% AM with 1 kHz A sine 1 A/m, 50Hz/60Hz, 3 axes A Reference standard EN 61000-4-2: 95 EN 61000-4-3: 96 ENV 50204: 95 EN 61000-4-4: 95 EN 61000-4-5: 95 EN 61000-4-6: 97 EN 61000-4-8: 97 30% Reduction for 25 cycles >95% Reduction for 250 cycles >95%, 0.5 cycles C EN 61000-4-11: 94 C B 2.13 Reliability Measurement type Nonrecoverable read errors Annualized Failure Rate (AFR) Load/Unload (U/UL) 25°C, 50% relative humidity 32°C, 80% relative humidity 5°C, 80% relative humidity 5°C, 10% relative humidity 55°C, 16% relative humidity Warranty Specification 1 per 1014 bits read, max. 0.5% 600,000 software-controlled power on/off cycles 50,000 hard power on/off cycles 600,000 software-controlled power on/off cycles 50,000 hard power on/off cycles Important: When returning a drive for warranty support, if possible, you should provide the valid ATA Master password, or return the drive in the Security Erased state with the User Data Area accessible. If these recommendations are not followed, Seagate cannot access the drive to perform failure analysis to verify your warranty claim. To determine the warranty for a specific drive, use a web browser to access the following web page: support.seagate.com/customer/warranty_validation.jsp You will be asked to provide the drive serial number, model number (or part number) and country of purchase. After submitting this information, the system will display the warranty information for your drive.. Momentus 7200 FDE.2 SATA Product Manual, Rev. B 15

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60

Momentus 7200 FDE.2 SATA Product Manual, Rev. B
15
2.13
Reliability
Measurement type
Specification
Nonrecoverable read errors
1 per 10
14
bits read, max.
Annualized Failure Rate (AFR)
0.5%
Load/Unload (U/UL)
25°C, 50% relative humidity
32°C, 80% relative humidity
5°C, 80% relative humidity
5°C, 10% relative humidity
55°C, 16% relative humidity
600,000 software-controlled power on/off cycles
50,000 hard power on/off cycles
600,000 software-controlled power on/off cycles
50,000 hard power on/off cycles
Warranty
Important:
When returning a drive for warranty support, if possible, you should
provide the valid ATA Master password, or return the drive in the Security Erased
state with the User Data Area accessible.
If these recommendations are not followed, Seagate cannot access the drive to
perform failure analysis to verify your warranty claim.
To determine the warranty for a specific drive, use a web browser to access the
following web page:
support.sea
gate.com/customer/warranty
_validation.jsp
You will be asked to provide the drive serial number, model number (or part num-
ber) and country of purchase. After submitting this information, the system will dis-
play the
warranty information for your drive..
Test
Description
Performance
level
Reference
standard
Electrostatic discharge
Contact, HCP, VCP:
±
4
kV; Air:
±
8 kV
B
EN 61000-4-2: 95
Radiated RF immunity
80 to 2,000 MHz, 10 V/m,
80% AM with 1 kHz sine
900 MHz, 3 V/m, 50% pulse modulation @ 200 Hz
A
EN 61000-4-3: 96
ENV 50204: 95
Electrical fast transient
±
1 kV on AC mains,
±
0.5 kV on external I/O
B
EN 61000-4-4: 95
Surge immunity
±
1 kV differential,
±
2 kV common, AC mains
B
EN 61000-4-5: 95
Conducted RF immunity
150 kHz to 80 MHz, 3 Vrms, 80% AM with 1 kHz
sine
A
EN 61000-4-6: 97
Power Frequency H-field
immunity
1 A/m, 50Hz/60Hz, 3 axes
A
EN 61000-4-8: 97
Voltage dips, interrupts
30% Reduction for 25 cycles
>95% Reduction for 250 cycles
>95%, 0.5 cycles
C
C