Sennheiser TeamConnect Ceiling 2 ES1 Ceiling Audio Solution TeamConnect Ceilin - Page 8
Control IP Address, LED Colors, LED Brightness, Digital Output Dante Gain, Logic Test, Microphone - default ip
View all Sennheiser TeamConnect Ceiling 2 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 8 highlights
Application Guide ES-1 Audio System Set-up Guide for Microsoft Teams A control object for the TCC2 integrates some important control parameters into the processor. Control IP Address Input the Control IP address of the TCC2, and then press Enter. The indicator box will be highlighted in blue to confirm the connection. A connection to the processor must be established to control all of the parameters.in this object. LED Colors Select the color of the LEDs in the Mute and Unmute states. For Microsoft Teams, the default colors are: Mute: Red Unmute: Green LED Brightness Use the fader to set the LED brightness when the LEDs are on. Select among five brightness levels. Select Off to turn the LEDs off. Digital Output (Dante) Gain This fader selects the gain of the microphone, per the room. Logic Test Call Status can be used to turn the LED off via logic operations when not in a conference. Turning the LED off is an operation of the LED Brightness setting; when turned on, the LED will illuminate at the previously configured brightness setting. Microphone Orientation Orientation is determined from a top-down view. Positions are based on the direction in which the Sennheiser logo is pointing. The default position of the Sennheiser logo is 0 degrees. Figure 9: Control panel for Sennheiser TCC2 with description of controls and indicators April 2020 Page 6