Sharp AL-1200 AL1200 Operation Manual - Page 35
by pressing the round projections near the side cover open button. The misfeed
View all Sharp AL-1200 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 35 highlights
MISFEED REMOVAL 3 Raise the fusing unit release lever and then close the side cover by pressing the round projections near the side cover open button. The misfeed ( ) indicator will go out and the ready ( ) indicator will light up. C Misfeed in the transport area 1 Lower the fusing unit release lever. Fusing unit release lever 2 Push gently on both sides of the front cover to open the cover. 6 Copier trouble? 3 Rotate the feeding roller in the direction of the arrow and gently remove the misfed paper from the exit area. Feeding roller 4 Raise the fusing unit release lever, close the front cover and then close the side cover by pressing the round projections near the side cover open button. The misfeed ( ) indicator will go out and the ready ( ) indicator will light up. When closing the covers, be sure to close the front cover securely and then close the side cover. If the covers are closed in the wrong order, the covers may be damaged. 34