Sharp PG A20X Operation Manual - Page 62
Removing and Installing, the Lamp Unit - bqc
UPC - 074000364004
View all Sharp PG A20X manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 62 highlights
Regarding the Lamp Removing and Installing the Lamp Unit Info • Be sure to remove the lamp unit using the handle. Be sure not to touch the glass surface of the lamp unit or the inside of the projector. • To avoid injury to yourself and damage to the lamp, be sure to carefully follow the steps below. • Do not loosen other screws except for the filter/lamp unit cover and lamp unit. • Please refer to the installation manual included with the lamp unit. 1 Press STANDBY on the projector STANDBY or on the remote control to put the projector into the standby mode. • Wait until the cooling fan stops. Warning! • Do not remove the lamp unit from the projector right after use. The lamp will be very hot and may cause burn or injury. 2 Disconnect the power cord. • Unplug the power cord from the AC socket. • Leave the lamp until it has fully cooled down (about 1 hour). 3 Change the air filter. • Change the air filter whenever you install the lamp unit (see pages 53 and 54). 4 Remove the filter/lamp unit cover. • Turn the projector over. Loosen the user service screw (1) that secures the filter/lamp unit cover. Pressing the tab (2), remove the filter/lamp unit cover (3). -58 PG-A20X_E_PDF_P51_62.p65 58 Lamp unit BQC-PGA20X//1 STANDBY button STANDBY button AC socket 1 3 User service screw 2 Tab 03.4.23, 9:59 AM