Sharp PG-B10S Operation Manual - Page 71
Resetting the Lamp Timer, Remove the lamp unit., Insert the new lamp unit. - reset lamp
![]() |
UPC - 074000364080
View all Sharp PG-B10S manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 71 highlights
5 Remove the lamp unit. • Loosen the securing screws from the lamp unit. Hold the lamp unit by the handle and pull it in the direction of the arrow. At this time, keep the lamp unit horizontal and do not tilt it. 6 Insert the new lamp unit. • Press the lamp unit firmly into the lamp unit compartment. Fasten the securing screws. 7 Replace the lamp unit cover. • Align the tab on the lamp unit cover (1) and place it while pressing the tab (2) to close it. Then tighten the user service screw (3) to secure the lamp unit cover. Info • If the lamp unit and lamp unit cover are not correctly installed, the power will not turn on, even if the power cord is connected to the projector. Resetting the Lamp Timer Reset the lamp timer after replacing the lamp. 1 Connect the power cord. • Plug the power cord into the AC socket of the projector. 2 Reset the lamp timer. • While simultaneously holding down and on the projector, press and on the projector. • "LAMP 0000H" is displayed, indicating that the lamp timer is reset. Info • Make sure to reset the lamp timer only when replacing the lamp. If you reset the lamp timer and continue to use the same lamp, this may cause the lamp to become damaged or explode. Handle Securing screws 1 2 3 User service screw AC socket ON button buttons AUTO SYNC button -67 Appendix