Sharp XG-PH70X XG-PH70X Operation Manual - Page 104

Troubleshooting

Page 104 highlights

Troubleshooting Problem No picture and no sound or projector does not start. Check • Projector power cord is not plugged into the wall outlet. • Power to the external connected devices is off. • The selected input mode is wrong. • Cables incorrectly connected to side panel of the projector. • Remote control batteries have run out. • External output has not been set when connecting notebook computer. • Cables incorrectly connected to the side panel of the projector. • "Bright" is set to minimum position. • The "BLACK SCREEN" function is working. Page 37 - 45 27-36 17 27 27-36 60 50 Sound is heard but no picture appears. Color is faded or poor. Picture is blurred; noise appears. Picture appears but no sound is heard. An unusual sound is occasionally heard from the cabinet. Maintenance indicator illuminates or blinks in red. • Image adjustments are incorrectly set. (INPUT 1, INPUT 2, INPUT 3 only) • Input signal type (RGB/Component) is incorrectly set. (INPUT 4, INPUT 5 only) • Video Input system is incorrectly set. • Adjust the focus. • The projection distance exceeds the focus range. • There is fog on the lens. If the projector is carried from a cold room into a warm room, or if it is suddenly heated, condensation may form on the surface of the lens and the image will become blurred. Please set up the projector at least one hour before it is to be used. If condensation should form, remove the power cord from the wall outlet and wait for it to clear. (Computer Input only) • Perform "Fine Sync" Adjustments. ("Clock" Adjustment) • Perform "Fine Sync" Adjustments. ("Phase" Adjustment) • Turn off the LCD display of the notebook computer. • Noise may appear depending on the computer. • Cables incorrectly connected to side panel of the projector. • Volume is set to minimum. • The "MUTE" function is working. • The "Speaker" menu is set to "OFF". • If the picture is normal, the sound is due to cabinet shrinkage caused by room temperature changes. This will not affect operation or performance. • See "Maintenance Indicators". 60 63 76 40 22 - 68 68 101 - 27-36 46 46 73 - 94 -102

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110

-102
Troubleshooting
Check
Projector power cord is not plugged into the wall outlet.
Power to the external connected devices is off.
The selected input mode is wrong.
Cables incorrectly connected to side panel of the projector.
Remote control batteries have run out.
External output has not been set when connecting notebook computer.
Cables incorrectly connected to the side panel of the projector.
“Bright” is set to minimum position.
The “BLACK SCREEN” function is working.
Image adjustments are incorrectly set.
(INPUT 1, INPUT 2, INPUT 3 only)
Input signal type (RGB/Component) is incorrectly set.
(INPUT 4, INPUT 5 only)
Video Input system is incorrectly set.
Adjust the focus.
The projection distance exceeds the focus range.
There is fog on the lens. If the projector is carried from a cold
room into a warm room, or if it is suddenly heated,
condensation may form on the surface of the lens and the
image will become blurred. Please set up the projector at least
one hour before it is to be used. If condensation should form,
remove the power cord from the wall outlet and wait for it to
clear.
(Computer Input only)
Perform “Fine Sync” Adjustments. (“Clock” Adjustment)
Perform “Fine Sync” Adjustments. (“Phase” Adjustment)
Turn off the LCD display of the notebook computer.
Noise may appear depending on the computer.
Cables incorrectly connected to side panel of the projector.
Volume is set to minimum.
The “MUTE” function is working.
The “Speaker” menu is set to “OFF”.
If the picture is normal, the sound is due to cabinet shrinkage
caused by room temperature changes. This will not affect
operation or performance.
See “Maintenance Indicators”.
Problem
An unusual sound is
occasionally heard
from the cabinet.
Maintenance
indicator illuminates or
blinks in red.
Page
37
45
27
36
17
27
27
36
60
50
60
63
76
40
22
68
68
101
27
36
46
46
73
94
Sound is heard but no
picture appears.
Color is faded or poor.
Picture is blurred;
noise appears.
Picture appears but no
sound is heard.
No picture and no sound
or projector does not start.