Sony CPD-E400 Operating Instructions - Page 18

Specifications - 19 crt monitor

Page 18 highlights

Self-diagnosis function This monitor is equipped with a self-diagnosis function. If there is a problem with your monitor or computer, the screen will go blank and the 1 (power) indicator will either light up green or flash orange. If the 1 (power) indicator is lit in orange, the computer is in power saving mode. Try pressing any key on the keyboard. RESET MENU 1 (power) indicator If the 1 (power) indicator is green 1 Disconnect the video input cable or turn off the connected computer. 2 Press the 1 (power) button twice to turn the monitor off and then on. 3 Move the control button , for 2 seconds before the monitor enters power saving mode. MENU If all four color bars appear (white, red, green, blue), the monitor is working properly. Reconnect the video input cable and check the condition of your computer. If the color bars do not appear, there is a potential monitor failure. Inform your authorized Sony dealer of the monitor's condition. If the 1 (power) indicator is flashing orange Press the 1 (power) button twice to turn the monitor off and then on. If the 1 (power) indicator lights up green, the monitor is working properly. If the 1 (power) indicator is still flashing, there is a potential monitor failure. Count the number of seconds between orange flashes of the 1 (power) indicator and inform your authorized Sony dealer of the monitor's condition. Be sure to note the model name and serial number of your monitor. Also note the make and model of your computer and video board. Specifications CRT Viewable image size Resolution Maximum Recommended Standard image area Deflection frequency* AC input voltage/current Power consumption Operating temperature Dimensions Mass Plug and Play Supplied accessories 0.24 mm aperture grille pitch (center) 19 inches measured diagonally 90-degree deflection FD Trinitron Approx. 365 × 274 mm (w/h) (14 3/8 × 10 7/8 inches) 18.0" viewing image Horizontal: 1800 dots Vertical: 1440 lines Horizontal: 1280 dots Vertical: 1024 lines Approx. 352 × 264 mm (w/h) (13 7/8 × 10 1/2 inches) Horizontal: 30 to 96 kHz Vertical: 48 to 120 Hz 100 to 240 V, 50 - 60 Hz, Max. 2.0 A 140 W 10°C to 40°C Approx. 446 × 464 × 461 mm (w/h/d) (17 5/8 × 18 3/8 × 18 1/4 inches) Approx. 26 kg (57 lb 5 oz) DDC1/DDC2B/DDC2Bi/GTF See page 6 * Recommended horizontal and vertical timing condition • Horizontal sync width should be more than 1.0 µsec. • Horizontal blanking width should be more than 3.0 µsec. • Vertical blanking width should be more than 500 µsec. Design and specifications are subject to change without notice. 18

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52

18
Self-diagnosis function
This monitor is equipped with a self-diagnosis function. If there is
a problem with your monitor or computer, the screen will go
blank and the
1
(power) indicator will either light up green or
flash orange. If the
1
(power) indicator is lit in orange, the
computer is in power saving mode. Try pressing any key on the
keyboard.
If the
1
(power) indicator is green
1
Disconnect the video input cable or turn off the
connected computer.
2
Press the
1
(power) button twice to turn the monitor
off and then on.
3
Move the control button
,
for 2 seconds before the
monitor enters power saving mode.
If all four color bars appear (white, red, green, blue), the monitor
is working properly. Reconnect the video input cable and check
the condition of your computer.
If the color bars do not appear, there is a potential monitor failure.
Inform your authorized Sony dealer of the monitor’s condition.
If the
1
(power) indicator is flashing orange
Press the
1
(power) button twice to turn the monitor off
and then on.
If the
1
(power) indicator lights up green, the monitor is working
properly.
If the
1
(power) indicator is still flashing, there is a potential
monitor failure. Count the number of seconds between orange
flashes of the
1
(power) indicator and inform your authorized
Sony dealer of the monitor’s condition. Be sure to note the model
name and serial number of your monitor. Also note the make and
model of your computer and video board.
Specifications
CRT
0.24 mm aperture grille pitch (center)
19 inches measured diagonally
90-degree deflection
FD Trinitron
Viewable image size
Approx. 365
×
274 mm (w/h)
(14
3
/
8
×
10
7
/
8
inches)
18.0" viewing image
Resolution
Maximum
Horizontal: 1800 dots
Vertical: 1440 lines
Recommended
Horizontal: 1280 dots
Vertical: 1024 lines
Standard image area
Approx. 352
×
264 mm (w/h)
(13
7
/
8
×
10
1
/
2
inches)
Deflection frequency*
Horizontal: 30 to 96 kHz
Vertical: 48 to 120 Hz
AC input voltage/current
100 to 240 V, 50 – 60 Hz, Max. 2.0 A
Power consumption
140 W
Operating temperature
10°C to 40°C
Dimensions
Approx. 446
×
464
×
461 mm
(w/h/d)
(17
5
/
8
×
18
3
/
8
×
18
1
/
4
inches)
Mass
Approx. 26 kg (57 lb 5 oz)
Plug and Play
DDC1/DDC2B/DDC2Bi/GTF
Supplied accessories
See page 6
*
Recommended horizontal and vertical timing condition
Horizontal sync width should be more than 1.0 μsec.
Horizontal blanking width should be more than 3.0 μsec.
Vertical blanking width should be more than 500 μsec.
Design and specifications are subject to change without notice.
MENU
RESET
1
(power) indicator
MENU