Sony DCR-TRV10 Service Manual - Page 110
Picture Frame Setting, AGC GAIN Calibration Adjustment, Switch setting, Setting method
View all Sony DCR-TRV10 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 110 highlights
8. Picture Frame Setting Subject Color bar chart (Color reproduction adjustment frame) (1.5m from the front of the lens) Measurement Point Video output terminal Measuring Instrument Oscilloscope and TV monitor Specified Value A=B, C=D, E=F Switch setting: 1) NIGHT SHOT OFF 2) DIGITAL ZOOM (Menu display OFF Setting method: 1) Adjust the zoom and the camera direction, and set to the specified position. 2) Mark the position of the picture frame on the monitor display, and adjust the picture frame to this position in following adjustments using "Color reproduction adjustment frame". Check on the oscilloscope 1. Horizontal period A=B B A C=D C D Fig. 5-1-8. 2. Vertical period E E=F F V Fig. 5-1-9. Check on the monitor TV (Underscanned mode) 9. AGC GAIN Calibration Adjustment Subject Clear chart (Color reproduction adjustment frame) Measurement Point Display data of page 1 (Note) Measuring Instrument Adjustment remote commander Adjustment Page E Adjustment Address 3A, 3B, 3C, 3D Specified Value Data1 : 0196 to 02D3 Data2 : 0B35 to 1669 Note: Displayed data of page 1 of the adjustment remote commander. 1 : XX : XX Display data Switch setting: 1) NIGHT SHOT OFF Adjusting method: 1) Select page: 0, address: 01, and set data: 01. 2) Select page: 6, address: 40, and set data: 02. 3) Select page: 6, address: 41, and set data: 01. 4) Select page: 6, address: 01, set data: 71, and press the PAUSE button of the adjustment remote commander. (The AGC gain calibration adjustment is performed and the adjustment data is stored in page: E, address: 3A to 3D.) 5) Select page: 6, address: 02, and check that the data is "01". 6) Select page: 6, address: 01, set data: 00, and press the PAUSE button. Checking method: 1) Select page: 0, address: 01, and set data: 01. 2) Select page: F, address: 10, set data: 47, and press the PAUSE button. 3) Select page: 6, address: 9A, and set data: 03. 4) Select page: 6, address: 01, set data: 9B, and press the PAUSE button. 5) Select page: 6, address: 02, and check that the data is "01". 6) Select page: 1, and check that the display data (Note) satisfies the specified value of data1. 7) Select page: 6, address: 01, set data: 00, and press the PAUSE button. 8) Select page: 6, address: 9A, and set data: 99. 9) Select page: 6, address: 01, set data: 9B, and press the PAUSE button. 10) Select page: 6, address: 02, and check that the data is "01". 11) Select page: 1, and check that the display data (Note) satisfies the specified value of data2. Processing after Completing Adjustments: 1) Select page: F, address: 10, set data: 00, and press the PAUSE button. 2) Select page: 6, address: 01, and set data: 00, and press the PAUSE button. 3) Select page: 6, address: 40, and set data: 00. 4) Select page: 6, address: 41, and set data: 00. 5) Select page: 6, address: 9A, and set data: 00. 6) Select page: 0, address: 01, and set data: 00. Color bar chart picture frame Monitor TV picture frame Fig. 5-1-10. 5-24