SYSTEM CONTROL SYSTEM ADJUSTMENT, Initialization of B, C, D, E, F Data
View all Sony DCR-TRV10 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 126 highlights
3-2. SYSTEM CONTROL SYSTEM ADJUSTMENT 1. Initialization of B, C, D, E, F Page Data If the B, C, D, E, F page data is erased due to some reason, perform "1-2. INITIALIZATION OF B, C, D, E, F PAGE DATA", of "5-1. CAMERA SECTION ADJUSTMENT" 2. Battery End Check (VC-217 board) Check the battery end voltage. Mode Camera recording Subject Arbitrary Switch setting 1) AUTO FOCUS OFF 2) LCD screen Closed 3) REC LAMP (Menu display ON Connection: 1) Connect the regulated power supply and the digital voltmeter to the battery terminal as shown in Fig. 5-3-4. Adjusting method: 1) Adjust the output voltage of the regulated power supply so that the digital voltmeter display is 6.0 ± 0.1Vdc. 2) Turn off the power supply. 3) Turn on the HOLD switch of the adjustment remote commander. 4) Turn on the power supply. 5) Load a cassette, and set to the camera recording mode. 6) Check that the REC LAMP is lit continuously. 7) Decrease the output voltage of the regulated power supply so that the digital voltmeter display is 5.50 ± 0.01Vdc. 8) Check that the REC LAMP blinks at 0.8 Hz. Regulated power supply 5.5 } 0.01 Vdc Digital volt meter Fig. 5-3-4. 5-40