Sony FCBEH3300 Product Manual (Tehnical Manual for new HD Block Cameras) - Page 30

VISCA Device Setting Command, For VISCA network administration, VISCA interface command

Page 30 highlights

VISCA Device Setting Command Before starting control of the FCB camera, be sure to send the Address command and the IF_Clear command using the broadcast function. For VISCA network administration  Address Sets an address of a peripheral device. Use when initializing the network, and receiving the following network change message.  Network Change Sent from the peripheral device to the controller when a device is removed from or added to the network. The address must be re-set when this message is received. Packet Address 88 30 01 FF Network Change X0 38 FF X = 9 to F: FCB camera address + 8 Note Always broadcasted. VISCA interface command  IF_Clear Clears the command buffers in the FCB camera and cancels the command currently being executed. Command Packet Reply Packet Note IF_Clear 8X 01 00 01 FF X0 50 FF IF_Clear (broadcast) 88 01 00 01 FF 88 01 00 01 FF X = 1 to 7: FCB camera address (For inquiry packet) X = 9 to F: FCB camera address +8 (For reply packet) VISCA interface and inquiry  CAM_VersionInq Returns information on the VISCA interface. Inquiry Inquiry Packet Reply Packet CAM_VersionInq 8X 09 00 02 FF Y0 50 GG GG HH HH JJ JJ KK FF Description GGGG = Vender ID (0020: Sony) HHHH = Model ID 045D:FCB-EH3400 045E:FCB-EH3300 0464:FCB-EH3410 0465:FCB-EH3310 JJJJ = ROM revision KK = Maximum socket #(02) X = 1 to 7: FCB camera address (For inquiry packet) X = 9 to F: FCB camera address +8 (For reply packet) Command List 30

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64

²0
Command List
VISCA Device Setting Command
Before starting control of the FCB camera, be sure to
send the Address command and the IF_Clear
command using the broadcast function.
For VISCA network administration
Address
Sets an address of a peripheral device. Use when
initializing the network, and receiving the following
network change message.
Network Change
Sent from the peripheral device to the controller
when a device is removed from or added to the
network. The address must be re-set when this
message is received.
Packet
Note
Address
88 30 01 FF
Always broadcasted.
Network Change
X0 38 FF
X = 9 to F: FCB camera address + 8
VISCA interface command
IF_Clear
Clears the command buffers in the FCB camera and
cancels the command currently being executed.
Command Packet
Reply Packet
Note
IF_Clear
8X 01 00 01 FF
X0 50 FF
IF_Clear (broadcast)
88 01 00 01 FF
88 01 00 01 FF
X = 1 to 7: FCB camera address (For inquiry packet)
X = 9 to F: FCB camera address +8 (For reply packet)
VISCA interface and inquiry
CAM_VersionInq
Returns information on the VISCA interface.
Inquiry
Inquiry Packet
Reply Packet
Description
CAM_VersionInq
8X 09 00 02 FF
Y0 50 GG GG HH HH JJ JJ KK FF
GGGG = Vender ID
(0020: Sony)
HHHH = Model ID
045D:FCB-EH3400
045E:FCB-EH3300
0464:FCB-EH3410
0465:FCB-EH3310
JJJJ = ROM revision
KK = Maximum socket #(02)
X = 1 to 7: FCB camera address (For inquiry packet)