Stihl MSE 140 C-BQ Product Instruction Manual - Page 32

Connecting Saw, to Power Supply

Page 32 highlights

Connecting Saw to Power Supply English / USA Chain brake maintenance The chain brake is subject to normal wear. It is necessary to have it serviced and maintained regularly by trained personnel. STIHL recommends that you have the maintenance and repair work performed by a STIHL servicing dealer at the following intervals: Full-time professional users: Semi-professional users (farm and construction industry): Hobby and occasional users: every 3 months every 6 months every 12 months The voltage of your power supply and the voltage specified on the saw must be the same. Outdoor operation: Connect the saw via a ground-fault circuit breaker. Extension cords must be suitable for outdoor use. Mains power outlet: Must be equipped with a fuse or automatic circuit breaker. If the fuse or circuit breaker is tripped when you switch on the saw, use an extension cord (at least 35 ft /10 m long) that meets the specifications in the following table. Extension cords: Minimum wire size for extension cords for 120 Volt appliances: Cord types SJW-A or SJTW-A Round jacketed cords. MSE 140 cord length (ft) 50 100 150 wire size (AWG) 14 12 10 MSE 180 cord length (ft) 50 wire size (AWG) 10 100 150 1) 1) 1) not recommended Listed by UL, W-A marking on cable jacket indicates "use outdoors". Appropriate extension cords are available in stores spezializing in electrical equipment. Cable drum: Always unwind the cord completely. It should be equipped with thermal protection. MSE 140 C, MSE 160 C, MSE 180 C, MSE 200 C 31

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94

31
MSE 140 C, MSE 160 C, MSE 180 C, MSE 200 C
English / USA
Chain brake maintenance
The chain brake is subject to normal
wear. It is necessary to have it serviced
and maintained regularly by trained
personnel. STIHL recommends that you
have the maintenance and repair work
performed by a STIHL servicing dealer
at the following intervals:
The
voltage of your power supply
and
the
voltage specified on the saw
must
be the same.
Outdoor operation:
Connect the saw
via a ground-fault circuit breaker.
Extension cords must be suitable for
outdoor use.
Mains power outlet:
Must be equipped
with a fuse or automatic circuit breaker.
If the fuse or circuit breaker is tripped
when you switch on the saw, use an
extension cord (at least 35 ft
/10 m long)
that meets the specifications in the
following table.
Extension cords:
1)
not recommended
Listed by UL, W-A marking on cable
jacket indicates "use outdoors".
Appropriate extension cords are
available in stores spezializing in
electrical equipment.
Cable drum:
Always unwind the cord
completely. It should be equipped with
thermal protection.
Full-time professional
users:
every 3
months
Semi-professional
users (farm and
construction industry):
every 6
months
Hobby and occasional
users:
every 12
months
Minimum wire size for extension cords
for 120 Volt appliances:
Cord types
SJW-A or SJTW-A
Round jacketed cords.
MSE 140
cord length (ft)
50
100
150
wire size (AWG)
14
12
10
MSE 180
cord length (ft)
50
100
150
wire size (AWG)
10
1)
1)
Connecting Saw
to Power Supply