Stihl SR 200 Product Instruction Manual - Page 23

Checking Flow Rate - accessories

Page 23 highlights

Metering Knob 1 2 N Rotate the metering knob (1) for infinitely variable discharge rate Position 1 = minimum flow rate Position 6 = maximum flow rate The numbers on the metering knob must be lined up with the lug (2) under the knob. Discharge Rate The discharge rate (l/min) depends on the metering knob setting and the spray tube angle. 0811BA019 KN 2431BA022 KN Discharge rate (l/min) without pressure pump Knob setting 1 2 3 4 5 6 Spray tube angle - 30° 0° + 30° 0.24 0.17 0.11 0.82 0.66 0.46 1.42 1.13 0.84 2.2 1.66 1.1 2.69 2.13 1.46 2.91 2.25 1.52 Discharge rate (l/min) without pressure pump, with ULV nozzle Knob setting 0.5 0.65 0.8 Spray tube angle - 30° 0° + 30° 0.05 0.04 0.03 0.08 0.07 0.05 0.12 0.09 0.08 Discharge rate (l/min) with pressure pump (special accessory) Knob setting 1.0 1.6 2.0 Spray tube angle - 30° 0° + 30° 0.64 1.7 2.59 Discharge rate (l/min) with pressure pump (special accessory) and ULV nozzle Knob setting 0.5 0.65 0.8 Spray tube angle - 30° 0° + 30° 0.15 0.2 0.37 Checking Flow Rate English N Place the unit on the ground. N Fill the container with water up to 10 liter mark. Machines without pressure pump N Set the "standard" metering knob to 6. N Start the machine. N Hold the spray tube horizontally, run the engine at full throttle, spray the contents of the container down to the 5 liter mark and note the time taken. The time required to spray 5 liters fluid should be between 110 and 150 seconds. Machines with pressure pump (special accessory) N Fit metering knob 2.0 in the nozzle. N Start the machine. N Hold the spray tube horizontally, run the engine at full throttle, spray the contents of the container down to the 5 liter mark and note the time taken. The time required to spray 5 liters fluid should be between 100 and 130 seconds. SR 200 21

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84

SR 200
English
21
Metering Knob
N
Rotate the metering knob (1) for
infinitely variable discharge rate
Position
1
= minimum flow rate
Position
6
= maximum flow rate
The numbers on the metering knob must
be lined up with the lug (2) under the
knob.
Discharge Rate
The discharge rate (l/min) depends on
the metering knob setting and the spray
tube angle.
Discharge rate (l/min) without pressure
pump
Discharge rate (l/min) without pressure
pump, with ULV nozzle
Discharge rate (l/min) with pressure
pump (special accessory)
Discharge rate (l/min) with pressure
pump (special accessory) and ULV
nozzle
Checking Flow Rate
N
Place the unit on the ground.
N
Fill the container with water up to
10 liter mark.
Machines without pressure pump
N
Set the "standard" metering knob to
6.
N
Start the machine.
N
Hold the spray tube horizontally, run
the engine at full throttle, spray the
contents of the container down to
the 5 liter mark and note the time
taken.
The time required to spray 5 liters fluid
should be between 110 and
150 seconds.
Machines with pressure pump (special
accessory)
N
Fit metering knob 2.0 in the nozzle.
N
Start the machine.
N
Hold the spray tube horizontally, run
the engine at full throttle, spray the
contents of the container down to
the 5 liter mark and note the time
taken.
The time required to spray 5 liters fluid
should be between 100 and
130 seconds.
2
1
2431BA022 KN
0811BA019 KN
Spray tube angle
Knob setting
- 30°
+ 30°
1
0.24
0.17
0.11
2
0.82
0.66
0.46
3
1.42
1.13
0.84
4
2.2
1.66
1.1
5
2.69
2.13
1.46
6
2.91
2.25
1.52
Spray tube angle
Knob setting
- 30°
+ 30°
0.5
0.05
0.04
0.03
0.65
0.08
0.07
0.05
0.8
0.12
0.09
0.08
Spray tube angle
Knob setting
- 30°
+ 30°
1.0
0.64
1.6
1.7
2.0
2.59
Spray tube angle
Knob setting
- 30°
+ 30°
0.5
0.15
0.65
0.2
0.8
0.37