BUILT-IN REFRIGERATION Electrical The electrical supply should be located within the shaded area shown in the illustration below. A separate circuit, servicing only this appliance is required. A ground fault circuit interrupter (GFCI) is not recommended and may cause interruption of operation. Installation must comply with all applicable electrical codes. ELECTRICAL REQUIREMENTS Electrical Supply Service Receptacle 115 VAC, 60 Hz 15 amp 3-prong grounding-type 7" (178) E 6" (152) 751/2" (1918) FROM FLOOR RIGHT SIDE OF OPENING Plumbing The water supply line should be located within the shaded area shown in the illustration below. The water supply line should be connected to the house supply with an easily accessible shut-off valve. Do not use self‑piercing valves. The water supply line must not interfere with installation of the anti-tip brackets. A reverse osmosis system can be used provided there is constant water pressure of 35-120 psi (2.4-8.3 bar) supplied to the unit at all times. A copper line is not recommended for this application. Installation must comply with all applicable plumbing codes. PLUMBING REQUIREMENTS Water Supply Pressure Excess Line for Connection 1/4" OD copper, braided stainless steel or PEX tubing 35-120 psi (2.4-8.3 bar) 36" (914) RIGHT SIDE OF OPENING Electrical supply location. 18" (457) 6" (152) 3" (76) AREA EXTENDS 1/2" (13) FORWARD ON FLOOR Water supply location. 16 | Sub-Zero Customer Care 800.222.7820