BUILT-IN REFRIGERATION Electrical The electrical supply should be located within the shaded area shown in the illustration below. A separate circuit, servicing only this appliance is required. A ground fault circuit interrupter (GFCI) is not recommended and may cause interruption of operation. Installation must comply with all applicable electrical codes. ELECTRICAL REQUIREMENTS Electrical Supply Service Receptacle 115 VAC, 60 Hz 15 amp 3-prong grounding-type 7" (178) E 6" (152) 751/2" (1918) FROM FLOOR RIGHT SIDE OF OPENING Plumbing The water supply line should be located within the shaded area shown in the illustration below. The water supply line should be connected to the house supply with an easily accessible shut-off valve. Do not use self‑piercing valves. The water supply line must not interfere with installation of the anti-tip brackets. A reverse osmosis system can be used provided there is constant water pressure of 35-120 psi (2.4-8.3 bar) supplied to the unit at all times. A copper line is not recommended for this application. Installation must comply with all applicable plumbing codes. PLUMBING REQUIREMENTS Water Supply Pressure Excess Line for Connection 1/4" OD copper, braided stainless steel or PEX tubing 35-120 psi (2.4-8.3 bar) 36" (914) RIGHT SIDE OF OPENING Electrical supply location. 18" (457) 6" (152) 3" (76) AREA EXTENDS 1/2" (13) FORWARD ON FLOOR Water supply location. 16 | Sub-Zero Customer Care 800.222.7820

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40

16
|
Sub-Zero Customer Care 800.222.7820
BUILT-IN REFRIGERATION
Plumbing
The water supply line should be located within the shaded
area shown in the illustration below. The water supply line
should be connected to the house supply with an easily
accessible shut-off valve. Do not use self-piercing valves.
The water supply line must not interfere with installation of
the anti-tip brackets.
A reverse osmosis system can be used provided there is
constant water pressure of 35–120 psi
(2.4–8.3 bar)
supplied
to the unit at all times. A copper line is not recommended
for this application.
Installation must comply with all applicable plumbing codes.
PLUMBING REQUIREMENTS
Water Supply
1
/
4
" OD copper, braided
stainless steel or PEX tubing
Pressure
35–120 psi
(2.4–8.3 bar)
Excess Line for Connection
36"
(914)
Electrical
The electrical supply should be located within the shaded
area shown in the illustration below. A separate circuit, ser-
vicing only this appliance is required. A ground fault circuit
interrupter (GFCI) is not recommended and may cause
interruption of operation.
Installation must comply with all applicable electrical codes.
ELECTRICAL REQUIREMENTS
Electrical Supply
115 VAC, 60 Hz
Service
15 amp
Receptacle
3-prong grounding-type
75
1
/
2
"
(1918)
FROM FLOOR
7"
(178)
E
6"
(152)
RIGHT SIDE
OF OPENING
Electrical supply location.
3"
(76)
18"
(457)
6"
(152)
RIGHT SIDE
OF OPENING
AREA EXTENDS
1
/
2
"
(13)
FORWARD ON FLOOR
Water supply location.