Sub-Zero BI-42UFD Built-In Design Guide - Page 31

Side Panel, Handle Hardware

Page 31 highlights

BUILT-IN REFRIGERATION Side Panel The custom side panels must be a minimum of 24" (610) deep and 1/2" (13) thick. Routing will be necessary for the side panel to fit flush against the side of the unit. Refer to the illustrations below. When installing a built-in unit with a custom side panel, an accessory kit is required. Stainless steel and white enamel side panels are available through an authorized Sub-Zero dealer. For local dealer information, visit the find a showroom section of our website, subzero.com. 24" (610) FRONT OF SIDE PANEL 1" (25) 17/8" (48) ROUT TO 1/8" (3) 17/8"(48) 1" (25) 84" (2134) 1/8" (3) 1/2" (13) MAIN SIDE PANEL FRAME ROUTING 41/4" (108) ROUT TO 3/16" (5) (OVER-AND-UNDER MODELS) 5 3/4" (146) 201/2" (521) 4" (102) OPTIONAL TOE KICK CUT-OUT 2 5/8" (67) Side panel dimensions. Routing detail. Handle Hardware Optional stainless steel tubular and pro handles are avail­ able through an authorized Sub-Zero dealer. For local dealer information, visit the find a showroom section of our website, subzero.com. Refer to the chart below for the length and stud spacing of standard handles for built-in models. STANDARD HANDLES FULL DOOR Tubular Pro OVER-AND-UNDER DOOR Tubular Pro 30" DRAWER Tubular Pro 36" DRAWER Tubular Pro 42" DRAWER Tubular Pro LENGTH 637/8" (1622) 453/16" (1147) LENGTH 441/4" (1124) 371/2" (952) LENGTH 245/16" (633) 179/16" (447) LENGTH 305/16" (770) 235/8" (600) LENGTH 365/16" (922) 295/8" (753) STUD SPACING 437/8" (1114) 437/8" (1114) STUD SPACING 361/4" (921) 361/4" (921) STUD SPACING 165/16" (414) 165/16" (414) STUD SPACING 225/16" (567) 225/16" (567) STUD SPACING 285/16" (719) 285/16" (719) subzero.com/specs | 31

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40

subzero.com/specs
|
31
Side Panel
The custom side panels must be a minimum of 24"
(610)
deep and
1
/
2
"
(13)
thick. Routing will be necessary for the
side panel to fit flush against the side of the unit. Refer to
the illustrations below.
When installing a built-in unit with a custom side panel, an
accessory kit is required. Stainless steel and white enamel
side panels are available through an authorized Sub-Zero
dealer. For local dealer information, visit the find a show-
room section of our website, subzero.com.
84"
(2134)
24"
(610)
ROUT TO
3
/
16
"
(5)
(OVER-AND-UNDER
MODELS)
OPTIONAL
TOE KICK
CUT-OUT
4"
(102)
20
1
/
2
"
(521)
5
3
/
4
"
(146)
1
7
/
8
"
(48)
1"
(25)
4
1
/
4
"
(108)
ROUT TO
1
/
8
"
(3)
FRONT
OF SIDE
PANEL
2
5
/
8
"
(67)
MAIN
FRAME
SIDE PANEL
ROUTING
1"
(25)
1
7
/
8
"
(48)
1
/
8
"
(3)
1
/
2
"
(13)
Side panel dimensions.
Routing detail.
BUILT-IN REFRIGERATION
Handle Hardware
Optional stainless steel tubular and pro handles are avail-
able through an authorized Sub-Zero dealer. For local dealer
information, visit the find a showroom section of our
website, subzero.com.
Refer to the chart below for the length and stud spacing of
standard handles for built-in models.
STANDARD HANDLES
FULL DOOR
LENGTH
STUD SPACING
Tubular
63
7
/
8
"
(1622)
43
7
/
8
"
(1114)
Pro
45
3
/
16
"
(1147)
43
7
/
8
"
(1114)
OVER-AND-UNDER DOOR
LENGTH
STUD SPACING
Tubular
44
1
/
4
"
(1124)
36
1
/
4
"
(921)
Pro
37
1
/
2
"
(952)
36
1
/
4
"
(921)
30" DRAWER
LENGTH
STUD SPACING
Tubular
24
5
/
16
"
(633)
16
5
/
16
"
(414)
Pro
17
9
/
16
"
(447)
16
5
/
16
"
(414)
36" DRAWER
LENGTH
STUD SPACING
Tubular
30
5
/
16
"
(770)
22
5
/
16
"
(567)
Pro
23
5
/
8
"
(600)
22
5
/
16
"
(567)
42" DRAWER
LENGTH
STUD SPACING
Tubular
36
5
/
16
"
(922)
28
5
/
16
"
(719)
Pro
29
5
/
8
"
(753)
28
5
/
16
"
(719)