BUILT-IN REFRIGERATION Overlay and Flush Inset Panels FULL-SCALE TEMPLATE Overlay and flush inset panels must be a minimum of 5/8" (16) thick to support mounting the handle. Panel thickness does not include backer and spacer panel. Mount handle close to the opening edge of the door. DEPTH OF TUBULAR AND PRO HANDLES 1" 2" 3" (25) (51) (76) 11/4" (32) PANEL 1" (25) PANEL 3/4" (19) PANEL 1/4" (6) BACKER PANEL .10" (3) SPACER PANEL DOOR Overlay and flush inset panel thickness. subzero.com/specs | 33
subzero.com/specs
|
33
Overlay and Flush Inset Panels
FULL-SCALE TEMPLATE
Overlay and flush inset panels must be a minimum of
5
/
8
"
(16)
thick to support mounting the handle. Panel thickness
does not include backer and spacer panel. Mount handle
close to the opening edge of the door.
BUILT-IN REFRIGERATION
Overlay and flush inset panel thickness.
1
/
4
"
(6)
BACKER PANEL
DOOR
DEPTH OF TUBULAR
AND PRO HANDLES
1"
(25)
3"
(76)
1
1
/
4
"
(32) PANEL
1"
(25) PANEL
3
/
4
"
(19) PANEL
2"
(51)
.10"
(3) SPACER PANEL