TASCAM DA-6400 DA-6400dp Owners Manual Addendum V3.10 - Page 44

Document corrections, Setting item

Page 44 highlights

DA-6400/DA-6400dp o The following has been added to "Settings for IF-MA64/EX and IF-MA64/BN cards" of "4 - Recording" in the DA-6400/DA6400dp Owner's Manual. When IF-MA64/EX installed Document corrections o The following error related to the IP SETUP screen has been corrected in "Network function settings" of "7 - Internal Settings" in the DA-6400/DA-6400dp Owner's Manual. MODE item default value correction Incorrect: STATIC (default), AUTO Correct: STATIC, AUTO (default) o The NOTE under "Remote control (Telnet)" of "7 - Internal Settings" in the DA-6400/DA-6400dp Owner's Manual contained an error that has been fixed. Correction of second NOTE item Incorrect: Telnet connection is not possible when the EXTERNAL Control item is set to LOCK on the LOCK SETUP screen. If the setting is changed to LOCK when there is a Telnet connection, the connection will be interrupted. Correct: When the EXTERNAL Control item is set to LOCK on the LOCK SETUP screen, Telnet connection is possible, but Telnet cannot be used to control this unit or change its settings. If the setting is changed to LOCK when there is a Telnet connection, the connection will not be interrupted, but Telnet will not longer be able to control this unit or change its settings. o The "List of keyboard operations" of "11 - Other Settings, Information Screens and Keyboard Operations" in the DA6400/DA-6400dp Owner's Manual contained an error that has been fixed. Full keyboard Enter key Incorrect: Same as pressing the MULTI JOG dial (add/delete mark) Correct: Same as pressing the MULTI JOG dial (add mark) Numeric keypad (transport operations only) Enter key Incorrect: Same as pressing the MULTI JOG dial (add/delete mark) Correct: Same as pressing the MULTI JOG dial (add mark) MADI COAXIAL EQUALIZER (same for both IF-MA64/EX and IF-MA64/BN) Set the equalizer for MADI COAXIAL input signals. When an IF-MA64/EX or IF-MA64/BN is connected and a low-voltage MADI COAXIAL signal source or long BNC cable is being used, proper reception is not possible sometimes. In this case, try setting MADI COAXIAL EQUALIZER to OFF. Options: ON (default), OFF o The table of setting items saved and loaded with system backup data in "Exporting/importing system backup data" of "11 - Other Settings, Information Screens and Keyboard Operations" in the DA-6400/DA-6400dp Owner's Manual contained errors that have been fixed. Incorrect Screen name MENU screen Page name Setting item IP SETUP NETWORK page DNS SETUP PASSWORD Correct Screen name MENU screen Page name Setting item IP SETUP NETWORK page DNS SETUP 44 TASCAM DA-6400/DA-6400dp Printed in China

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44

Printed in China
o
The following has been added to “Settings for IF-MA64/EX
and IF-MA64/BN cards” of “4 – Recording” in the DA-6400/DA-
6400dp Owner's Manual.
When IF-MA64/EX installed
MADI COAXIAL EQUALIZER
(same for both IF-MA64/EX and
IF-MA64/BN)
Set the equalizer for MADI COAXIAL input signals.
When an IF-MA64/EX or IF-MA64/BN is connected and a
low-voltage MADI COAXIAL signal source or long BNC cable is
being used, proper reception is not possible sometimes.
In this case, try setting
MADI COAXIAL EQUALIZER
to
OFF
.
Options:
ON
(default),
OFF
Document corrections
o
The following error related to the IP SETUP screen has been
corrected in “Network function settings” of “7 – Internal
Settings” in the DA-6400/DA-6400dp Owner's Manual.
MODE
item default value correction
Incorrect:
STATIC
(default),
AUTO
Correct:
STATIC
,
AUTO
(default)
o
The NOTE under “Remote control (Telnet)” of “7 – Internal
Settings” in the DA-6400/DA-6400dp Owner's Manual
contained an error that has been fixed.
Correction of second NOTE item
Incorrect: Telnet connection is not possible when the
EXTERNAL Control
item is set to
LOCK
on the
LOCK SETUP
screen. If the setting
is changed to
LOCK
when there is a Telnet
connection, the connection will be interrupted.
Correct: When the
EXTERNAL Control
item is set
to
LOCK
on the
LOCK SETUP
screen, Telnet
connection is possible, but Telnet cannot be
used to control this unit or change its settings.
If the setting is changed to
LOCK
when there is
a Telnet connection, the connection will not be
interrupted, but Telnet will not longer be able to
control this unit or change its settings.
o
The “List of keyboard operations” of “11 – Other Settings,
Information Screens and Keyboard Operations” in the DA-
6400/DA-6400dp Owner's Manual contained an error that
has been fixed.
Full keyboard
Enter key
Incorrect: Same as pressing the
MULTI JOG
dial
(add/delete mark)
Correct: Same as pressing the
MULTI JOG
dial
(add mark)
Numeric keypad (transport operations only)
Enter key
Incorrect: Same as pressing the
MULTI JOG
dial
(add/delete mark)
Correct: Same as pressing the
MULTI JOG
dial
(add mark)
o
The table of setting items saved and loaded with system
backup data in “Exporting/importing system backup data”
of “11 – Other Settings, Information Screens and Keyboard
Operations” in the DA-6400/DA-6400dp Owner's Manual
contained errors that have been fixed.
Incorrect
Screen name
Page name
Setting item
MENU
screen
NETWORK page
IP SETUP
DNS SETUP
PASSWORD
Correct
Screen name
Page name
Setting item
MENU
screen
NETWORK page
IP SETUP
DNS SETUP
44
TASCAM
DA-6400/DA-6400dp
DA-6400/DA-6400dp