Thermador ME302WS View Kitchen Design and Planning Guide - Page 107

Inch Built-In Freezer Column With Internal Ice Maker - T36IF905SP

Page 107 highlights

| THERMADOR | FREEDOM® REFRIGERATION | THERMADOR | FREEDOM® REFRIGERATION INSTALLATION Freedom® Collection 30-Inch Built-In Freezer Column With Internal Ice Maker - T30IF905SP Cutout Dimensions 30" (762 mm) 84"-851/16" C (2134 mm2164 mm) A Furniture return A: Area for installation of power connection. B: Area for running the water line. It is recommended that the waterbox is placed adjacent to the installation cavity, so that it can be accessed for service without uninstalling the appliance. If this is not possible, place the recessed waterbox adjacent to the water supply socket elevated at the heights as referenced in areas A and B. C: Niche depth depends on kitchen design. For a flush installation, the depth needs to be at least 24 inches plus the thickness of the door panel. Stainless steel models contain a panel-ready base unit, ready-to-install stainless steel door(s) with a right or left door swing and handle(s). B min. 4" (102 mm) 4" (102 mm) B Top View Clearance 30" (762 mm) 145/16"** (364 mm) 1/8" (3 mm) 24" (610 mm) 1/8" (3 mm) 115° 90° 293/4" (756 mm) 33" (830 mm) ** Door handle must be added to this dimension * Depends on the thickness of the unit door. 3/4" (19 mm) refers to the stainless steel door. (special accessory). 3/4" (19 mm)* Panel Dimensions 293/4" (756 mm) 24" (610 mm) 293/4" (756 mm) 84" (2134 mm) 71/8" (181 mm) 213/16"-43/16" (72-106 mm) 24" (610 mm) 797/8" (2029 mm) 293/4" (756 mm) 4" (102 mm) 4" (102 mm) 797/8" (2029 mm) variable waterconnection at the appliance 210 Visit Thermador.com for complete specifications or text a Thermador model number to 21432 to have specs sent to your phone INSTALLATION Freedom® Collection 36-Inch Built-In Freezer Column With Internal Ice Maker - T36IF905SP Cutout Dimensions 36" (914 mm) 84"-851/16" C (2134 mm2164 mm) A Furniture return A: Area for installation of power connection. B: Area for running the water line. It is recommended that the waterbox is placed adjacent to the installation cavity, so that it can be accessed for service without uninstalling the appliance. If this is not possible, place the recessed waterbox adjacent to the water supply socket elevated at the heights as referenced in areas A and B. C: Niche depth depends on kitchen design. For a flush installation, the depth needs to be at least 24 inches plus the thickness of the door panel. Stainless steel models contain a panel-ready base unit, ready-to-install stainless steel door(s) with a right or left door swing and handle(s). B min. 4" (102 mm) 4" (102 mm) B Top View Clearance 36" (914 mm) 167/8"** (428 mm) 1/8" (3 mm) 24" (610 mm) 1/8" (3 mm) 115° 90° 353/4" (908 mm) 3811/16" (980 mm) ** Door handle must be added to this dimension * Depends on the thickness of the furniture door. 3/4" (19 mm) is relevant for the stainless steel door. (special Accessory). 3/4" (19 mm)* Panel Dimensions 353/4" (908 mm) 24" (610 mm) 353/4" (908 mm) 84" (2134 mm) 797/8" (2029 mm) 797/8" (2029 mm) 71/8" (181 mm) 213/16"-43/16" (72-106 mm) 24" (610 mm) 353/4" (908 mm) 4" (102 mm) 4" (102 mm) variable waterconnection at the appliance Visit Thermador.com for complete specifications or text a Thermador model number to 21432 to have specs sent to your phone 211

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131

211
210
30-Inch Built-In Freezer Column With Internal Ice Maker – T30IF905SP
36-Inch Built-In Freezer Column With Internal Ice Maker – T36IF905SP
Cutout Dimensions
Top View Clearance
Panel Dimensions
INSTALLATION
Freedom
®
Collection
INSTALLATION
Freedom
®
Collection
Cutout Dimensions
Top View Clearance
Panel Dimensions
|
THERMADOR
|
FREEDOM
®
REFRIGERATION
|
THERMADOR
|
FREEDOM
®
REFRIGERATION
min. 4"
(102 mm)
30" (762 mm)
(2134 mm-
2164 mm)
Furniture return
Stainless steel models contain a panel-ready base unit,
ready-to-install stainless steel door(s) with a right or left
door swing and handle(s).
4" (102 mm)
A:
Area for installation of power connection.
B:
Area for running the water line. It is recommended that the
waterbox is placed adjacent to the installation cavity, so that it
can be accessed for service without uninstalling the appliance.
If this is not possible, place the recessed waterbox adjacent to
the water supply socket elevated at the heights as referenced
in areas A and B.
C:
Niche depth depends on kitchen design. For a flush
installation, the depth needs to be at least 24 inches plus
the thickness of the door panel.
84"-85
1
/
16
"
A
B
C
B
* Depends on the thickness
of the unit door.
3/
4
" (19 mm) refers to the stainless
steel door. (special accessory).
90°
°
115
** Door handle must be added
to this dimension
14
5
/
16
"**
(364 mm)
24"
(610 mm)
33"
(830 mm)
30" (762 mm)
29
3
/
4
"
(756 mm)
1
/
8
"
(3 mm)
1
/
8
"
(3 mm)
3/
4" (19 mm)*
2
13
/
16
"-4
3
/
16
"
(72-106 mm)
variable water-
connection at
the appliance
29
3
/
4
"
(756 mm)
84"
(2134 mm)
79
7
/
8
"
(2029 mm)
7
1
/
8
" (181 mm)
29
3
/
4
"
(756 mm)
4" (102 mm)
24"
(610 mm)
79
7
/
8
"
(2029 mm)
29
3
/
4
"
(756 mm)
24" (610 mm)
4"
(102 mm)
2
13
/
16
"-4
3
/
16
"
(72-106 mm)
variable water-
connection
at the appliance
35
3
/
4
"
(908 mm)
84"
(2134 mm)
79
7
/
8
"
(2029 mm)
7
1
/
8
" (181 mm)
35
3
/
4
"
(908 mm)
4" (102 mm)
24"
(610 mm)
79
7
/
8
"
(2029 mm)
35
3
/
4
"
(908 mm)
24" (610 mm)
4"
(102 mm)
min. 4"
(102 mm)
36" (914 mm)
(2134 mm-
2164 mm)
Stainless steel models contain a panel-ready base unit,
ready-to-install stainless steel door(s) with a right or left
door swing and handle(s).
A:
Area for installation of power connection.
B:
Area for running the water line. It is recommended that the
waterbox is placed adjacent to the installation cavity, so that it
can be accessed for service without uninstalling the appliance.
If this is not possible, place the recessed waterbox adjacent to
the water supply socket elevated at the heights as referenced
in areas A and B.
C:
Niche depth depends on kitchen design. For a flush
installation, the depth needs to be at least 24 inches plus
the thickness of the door panel.
Furniture return
4" (102 mm)
84"-85
1
/
16
"
A
B
C
B
* Depends on the thickness
of the furniture door.
3/
4
" (19 mm) is relevant for the
stainless steel door.
(special Accessory).
90°
115°
** Door handle must be added
to this dimension
16
7
/
8
"**
(428 mm)
36" (914 mm)
24"
(610 mm)
38
11
/
16
"
(980 mm)
35
3
/
4
"
(908 mm)
1
/
8
"
(3 mm)
1
/
8
"
(3 mm)
3/
4" (19 mm)*
Visit Thermador.com for complete speciFcations or text a Thermador model number to 21432 to have specs sent to your phone
Visit Thermador.com for complete speciFcations or text a Thermador model number to 21432 to have specs sent to your phone