Thermador ME302WS View Kitchen Design and Planning Guide - Page 75

Electric Load 120V, 60Hz

Page 75 highlights

PLANNING INFORMATION Wall Chimney Hoods Model Options Thermador Wall Chimney Hoods feature sleek styling and numerous convenience functions. Wall Chimney Hoods are available in 30-inch, 36-inch and 48-inch widths and are adjustable to suit a range of ceiling heights. All stainless steel or stainless steel with glass designs are available. Be sure to reference the correct model information in this design guide. Electrical Specifications Be sure your Thermador Wall Chimney Hood is properly installed and grounded by a qualified technician. Installation, electrical connections and grounding must comply with all applicable local codes. If possible, site the earthed socket directly behind the chimney paneling. The grounded socket should be connected via its own circuit. If the grounded socket is no longer accessible following installation of the hood, ensure that there is a permanently installed disconnector. HPCN48WS HPCN36WS HMCB36WS, HMCB30WS, HDDB36WS, HDDB30WS Amps Watts Amps Watts - Remote Blower VTR2FZ 11.1 1,332 10.3 1,236 - Installation Considerations The information in this design guide provides key features, product dimensions, cutouts and installation specifications. Before installing a Thermador Wall Chimney Hood, be sure to verify the cutout dimensions and electrical connections. Installation instructions are subject to change. Always consult with the installation manual included with the product for complete details prior to the installation. Installation Options Thermador Wall Chimney Hoods may be installed above a Thermador Range or Cooktop to create a convenient cooking center. Refer to the ventilation selection guide for compatibility. Hood installation height above a range or cooktop can vary. To obtain the necessary installation height above a Thermador Range or Cooktop, consult the appliance's installation manual. An accessory Hood Extension can be used to fill the space between the hood and ceiling. Thermador Wall Hoods can be mounted on a wall or suspended from a cabinet. The cabinet must be structurally joined to the wall studs to support the weight of this hood. Electric Load (120V, 60Hz) Inline Blower VTI2FZ 11.1 1,332 10.3 1,236 - Integrated Blower VTN2FZ 9.5 1,140 8.7 1,044 Blower Included, 4.9 INSTALLATION Wall Chimney Hoods HPCN48WS Wall Chimney Hood (48-Inch Width) HMCB36WS Wall Chimney Hood With Blower (36-Inch Width) HDDB36WS Wall Chimney Drawer Hood (36-Inch Width) HPCN36WS Wall Chimney Hood (36-Inch Width) HMCB30WS Wall Chimney Hood With Blower (30-Inch Width) HDDB30WS Wall Chimney Drawer Hood (30-Inch Width) | THERMADOR | VENTILATION | THERMADOR | VENTILATION 146 Visit Thermador.com for complete specifications or text a Thermador model number to 21432 to have specs sent to your phone 147

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131

147
146
Model Options
Thermador Wall Chimney Hoods feature sleek styling and numerous
convenience functions. Wall Chimney Hoods are available in 30-inch,
36-inch and 48-inch widths and are adjustable to suit a range of ceiling
heights. All stainless steel or stainless steel with glass designs are
available. Be sure to reference the correct model information in this
design guide.
Electrical SpeciFcations
Be sure your Thermador Wall Chimney Hood is properly installed and
grounded by a qualified technician. Installation, electrical connections
and grounding must comply with all applicable local codes.
If possible, site the earthed socket directly behind the chimney
paneling. The grounded socket should be connected via its own circuit.
If the grounded socket is no longer accessible following installation of
the hood, ensure that there is a permanently installed disconnector.
Installation Considerations
The information in this design guide provides key features, product
dimensions, cutouts and installation specifications. Before installing
a Thermador Wall Chimney Hood, be sure to verify the cutout
dimensions and electrical connections. Installation instructions are
subject to change. Always consult with the installation manual included
with the product for complete details prior to the installation.
Installation Options
Thermador Wall Chimney Hoods may be installed above a Thermador
Range or Cooktop to create a convenient cooking center. Refer to the
ventilation selection guide for compatibility.
Hood installation height above a range or cooktop can vary. To
obtain the necessary installation height above a Thermador Range
or Cooktop, consult the appliance’s installation manual. An accessory
Hood Extension can be used to fill the space between the hood
and ceiling.
Thermador Wall Hoods can be mounted on a wall or suspended from
a cabinet. The cabinet must be structurally joined to the wall studs to
support the weight of this hood.
PLANNING INFORMATION
Wall Chimney Hoods
INSTALLATION
Wall Chimney Hoods
HPCN48WS
Wall Chimney Hood (48-Inch Width)
HDDB36WS
Wall Chimney Drawer Hood (36-Inch Width)
HDDB30WS
Wall Chimney Drawer Hood (30-Inch Width)
HMCB36WS
Wall Chimney Hood With Blower (36-Inch Width)
HMCB30WS
Wall Chimney Hood With Blower (30-Inch Width)
HPCN36WS
Wall Chimney Hood (36-Inch Width)
|
THERMADOR
|
VENTILATION
|
THERMADOR
|
VENTILATION
Visit Thermador.com for complete speciFcations or text a Thermador model number to 21432 to have specs sent to your phone
Electric Load (120V, 60Hz)
Remote Blower
Inline Blower
Integrated Blower
VTR2FZ
VTI2FZ
VTN2FZ
HPCN48WS
Amps
11.1
11.1
9.5
Watts
1,332
1,332
1,140
HPCN36WS
Amps
10.3
10.3
8.7
Watts
1,236
1,236
1,044
HMCB36WS, HMCB30WS,
HDDB36WS, HDDB30WS
Blower Included, 4.9