| THERMADOR | COOKTOPS | THERMADOR | COOKTOPS PLANNING INFORMATION Induction Cooktops Model Options Models are available in our heritage black finish as well as our Freedom® dark gray glass, Liberty® titanium gray glass and silver mirrored finish for those who want a bold, striking alternative that goes perfectly with stainless steel appliances. Be sure to reference the correct model information in this design guide. Installation Considerations The information in this design guide provides key features, product dimensions, cutouts and installation specifications. Before installing a Thermador Induction Cooktop, be sure to verify the cutout dimensions and electrical connections. Installation instructions are subject to change. Always consult with the installation manual included with the product for complete details prior to the installation. Thermador Masterpiece® Induction Cooktops may be installed above a Thermador Oven, as long as the minimum distance between the cabinet floor and countertop is maintained. Reference the installation pages in this guide for details on installing above a conventional oven, steam oven, and microwave / speed oven. Thermador Induction Cooktops may also be installed above a Thermador Warming Drawer to create a convenient cooking center. Refer to the warming drawer section for additional specifications. Model CIT36YWB CIT36YWBB CIT367YGS CIT367YG CIT367YMS CIT367YM CIT365YB CIT30YWBB CIT304YM CIT304YB Approved Cooktop Over Thermador Oven Installation Ventilation Requirements We strongly recommend that a Thermador Ventilation Hood be installed with all Thermador Masterpiece® Induction Cooktops. The hood must be installed according to instructions furnished with the hood. Refer to the ventilation section or www.Thermador.com for a complete selection of ventilation options, blowers, and accessories. Warning To reduce the risk of ignition of nearby combustible materials, install the countertop with a minimum distance of 2" (51 mm) from both side walls and the back wall. Electrical Specifications Be sure your appliance is properly installed and grounded by a qualified technician. Installation, electrical connections and grounding must comply with all applicable local codes. All induction cooktops are dual rated, designed to be connected to either 240 / 208V AC, 60 Hz, 3-wire, single-phase power supply. Install a suitable conduit box (not furnished). An appropriately-sized, UL-listed conduit connector must be used to correctly attach the conduit to the junction box. Model CIT36YWB CIT36YWBB CIT367YGS CIT367YG CIT367YMS CIT367YM CIT365YB CIT30YWBB CIT304YM CIT304YB Required Circuit Breaker 240 / 208V, 3-Wire, 50 / 60 Hz 30 A 30 A 50 A 50 A 50 A 50 A 50 A 30 A 30 A 30 A IMPORTANT: Local Codes may vary; installation, electrical connections and grounding must comply with all applicable local codes. If required by the National Electrical Code (or Canadian Electrical Code), this appliance must be installed on a separate branch circuit. Electrical Location The junction box must be located within 3 feet (~900 mm) of the cooktop connection. It should be easily accessible for service purposes. Installation Requirements For safety reasons, the provided heat shield must be installed when closed cabinets are used. Some solid surface countertops require special installation. For example, heat reflective tape or rounded corners may be necessary. Contact the countertop manufacturer for instructions specific to your countertop. 112 Visit Thermador.com for complete specifications or text a Thermador model number to 21432 to have specs sent to your phone INSTALLATION Induction Cooktops 36-Inch Cooktop and Cutout Dimensions CIT36YWB *** 30" (762 mm) 37" (940 mm) 211/4" (540 mm) ** 41/8" (105 mm) * 23/8" (63 mm) 343/4" (883 mm) 197/8" (505 mm) * 1" (25,4 mm) 21/2" flat area (64 mm) setback distance * Minimum distance from cutout to the wall CIT36*Y* WIrnesBqtuaBilrleedd depth includes air gap 1" (26 mm) *** Minimum distance between the surface of the cooktop and the lower edge of the exhaust hood. measurements in inches (mm) NOTE: The work surface should be horizontal and level. The stability of the countertop should be confirmed even after making the cutout. * Minimum distance from cutout to the wall ** Installed depth includes 1" (26 mm) required air gap *** Minimum distance between the surface of the cooktop and the lower edge of the exhaust hood. measurements in inches (mm) CIT367YGS, CIT367YG, CIT367YMS, CIT367YM, CIT365YB *** 30" (762 mm) 37" (940 mm) 211/4" (540 mm) *** 30" (762) ** 41/8" 37" (940) 211/4" (540) (105 mm) 343/4"-347/8" * 2" (883-886 mm) (51 mm) 197/8"-20" (505-508 mm) **41/8" (105) 343/4 -347/8" 197/8 -20" (505-508) *2" (883-886) (51) * 2" (51 mm) flat area 21/2" (64 mm) setback distance * Minimum distance from cutout to the wall *2" (51) Flat area 21/4" (57) Distance from the edge Visit Ther*m* adIrneorsq.ctuaoimlrleefddoradcieormpgtpahlpeitnecslpuedciefisca1ti"on(2s 6ormtemxt)a Thermador model number to 21*432Mtoinhiamveumspeccslesaenrtatnocyeoufrropmhonceutout to wall 113 *** Minimum distance between the surface of the cooktop and the lower edge of the exhaust hood. ** Installed depth includes a gap of 1" (26 mm) for ventilation

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131

113
112
Model Options
Models are available in our heritage black finish as well as our Freedom
®
dark gray glass, Liberty
®
titanium gray glass and silver mirrored finish
for those who want a bold, striking alternative that goes perfectly
with stainless steel appliances. Be sure to reference the correct model
information in this design guide.
Installation Considerations
The information in this design guide provides key features, product
dimensions, cutouts and installation specifications. Before installing
a Thermador Induction Cooktop, be sure to verify the cutout
dimensions and electrical connections. Installation instructions are
subject to change. Always consult with the installation manual included
with the product for complete details prior to the installation.
Thermador Masterpiece
®
Induction Cooktops may be installed above
a Thermador Oven, as long as the minimum distance between the
cabinet floor and countertop is maintained. Reference the installation
pages in this guide for details on installing above a conventional oven,
steam oven, and microwave / speed oven.
Thermador Induction Cooktops may also be installed above a
Thermador Warming Drawer to create a convenient cooking center.
Refer to the warming drawer section for additional specifications.
Ventilation Requirements
We strongly recommend that a Thermador Ventilation Hood be
installed with all Thermador Masterpiece
®
Induction Cooktops. The
hood must be installed according to instructions furnished with the
hood. Refer to the ventilation section or www.Thermador.com for a
complete selection of ventilation options, blowers, and accessories.
Installation Requirements
For safety reasons, the provided heat shield must be installed when
closed cabinets are used. Some solid surface countertops require
special installation. For example, heat reflective tape or rounded
corners may be necessary. Contact the countertop manufacturer for
instructions specific to your countertop.
IMPORTANT:
Local Codes may vary; installation, electrical connections
and grounding must comply with all applicable local codes. If required
by the National Electrical Code (or Canadian Electrical Code), this
appliance must be installed on a separate branch circuit.
Electrical Location
The junction box must be located within 3 feet (~900 mm) of the
cooktop connection. It should be easily accessible for service purposes.
Warning
To reduce the risk of ignition of nearby combustible materials, install the
countertop with a minimum distance of 2" (51 mm) from both side walls
and the back wall.
Electrical SpeciFcations
Be sure your appliance is properly installed and grounded by a qualified
technician. Installation, electrical connections and grounding must
comply with all applicable local codes.
All induction cooktops are dual rated, designed to be connected to
either 240 / 208V AC, 60 Hz, 3-wire, single-phase power supply.
Install a suitable conduit box (not furnished). An appropriately-sized,
UL-listed conduit connector must be used to correctly attach the
conduit to the junction box.
Model
Approved Cooktop Over
Thermador Oven Installation
CIT36YWB
CIT36YWBB
CIT367YGS
CIT367YG
CIT367YMS
CIT367YM
CIT365YB
CIT30YWBB
CIT304YM
CIT304YB
Model
Required Circuit Breaker
240 / 208V, 3-Wire, 50 / 60 Hz
CIT36YWB
30 A
CIT36YWBB
30 A
CIT367YGS
50 A
CIT367YG
50 A
CIT367YMS
50 A
CIT367YM
50 A
CIT365YB
50 A
CIT30YWBB
30 A
CIT304YM
30 A
CIT304YB
30 A
PLANNING INFORMATION
Induction Cooktops
INSTALLATION
Induction Cooktops
|
THERMADOR
|
COOKTOPS
|
THERMADOR
|
COOKTOPS
Visit Thermador.com for complete speciFcations or text a Thermador model number to 21432 to have specs sent to your phone
Visit Thermador.com for complete speciFcations or text a Thermador model number to 21432 to have specs sent to your phone
Flat area
Distance from
the edge
21
(57)
(105)
(540)
(51)
(51)
(883-886)
(940)
(505-508)
(762)
2
1
/
4
"
**4
1
/
8
"
1
/
4
"
*2"
*2"
34
3
/
4
-34
7
/
8
"
37"
19
7
/
8
-20"
*** 30"
36-Inch Cooktop and Cutout Dimensions
CIT36YWB
CIT367YGS, CIT367YG, CIT367YMS,
CIT367YM, CIT365YB
CIT36YWBB
2
1/
2
"
(64 mm)
setback
distance
** 4
1/
8
"
(105 mm)
*** 30"
(762 mm)
21
1/
4
"
(540 mm)
* 1" (25,4 mm)
flat area
* 2
3/
8
"
(63 mm)
34
3/
4
"
(883 mm)
37"
(940 mm)
19
7/
8
"
(505 mm)
NOTE:
The work sur±ace should be horizontal and level.
The stability o± the countertop should be confrmed even
a±ter making the cutout.
*
Minimum distance from cutout to the wall
** Installed depth includes 1" (26 mm)
required air gap
*** Minimum distance between the surface
of the cooktop and the lower edge of the
exhaust hood.
measurements in inches (mm)
2
1/
2
"
(64 mm)
setback
distance
** 4
1/
8
"
(105 mm)
*** 30"
(762 mm)
21
1/
4
"
(540 mm)
* 2" (51 mm)
flat area
* 2"
(51 mm)
34
3/
4
"-34
7/
8
"
(883-886 mm)
37"
(940 mm)
19
7/
8
"-20"
(505-508 mm)