Toshiba Satellite A350 Maintenance Manual - Page 94
the following checks., computer following the steps described
View all Toshiba Satellite A350 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 94 highlights
582 Troubleshooting Procedures The Finger printer board or system board may be the reason of a finger printer fault. Either of these two components may be damaged. To determine if the computer's Finger printer is functioning properly, perform the following procedures. Figure 2-22 outlines the process. Start with Procedure 1 and continue with the other procedures as instructed. Procedure 1: Diagnostic test Procedure 2: Connector and replacement check Procedure 1 Diagnostic test Run the Diagnostic Program, which will automatically execute the Finger printer test. Tests and Diagnostics for more information on the program. If an error is located, go to Procedure 2. If an error is not located, the Finger printer system is functioning properly. Procedure 2 Connector and replacement check The Finger printer board or system board may be disconnected or damaged. Disassemble the computer following the steps described in Chapter 4, Replacement Procedures, and perform the following checks. Check 1 Make sure that the Finger printer board FFC is securely slotted into the system board. If the problem persists, go to Check 2. Check 2 The Finger printer board may be damaged. Replace it with a new one following the instructions in Chapter 4. If the problem still exists, perform Check 3. Check 3 The system board may be damaged. Replace it with a new one following the instructions in Chapter 4. Satellite A350, SATEGO A350, EQUIUM A350 Series Maintenance Manual 58