Toshiba Tecra M2 Maintenance Manual - Page 61
Procedure 2, Error Code Check, 3 Power Supply Troubleshooting, Troubleshooting Procedures, Table 2-3
View all Toshiba Tecra M2 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 61 highlights
2.3 Power Supply Troubleshooting 2 Troubleshooting Procedures Procedure 2 Error Code Check If the power supply microprocessor detects a malfunction, it indicates the error code as shown below. The error code begins with the least significant digit. Table 2-3 Error code Error code Where Error occurs 1*h Adaptor (AC Adaptor, DS) 2*h 1st battery 3*h 2nd Battery 4*h S3V output 5*h 1R5-C1V output 6*h 1R8-C1V output AC Adaptor is not connected. Error code begins with : 0x10 Error code ends with : 0x1F The 1st Battery is not connected. Error code begins with : 0x20 Error code ends with : 0x2F The 2nd Battery is not connected. Error code begins with : 0x30 Error code ends with : 0x3F Operating Power ON Error code begins with : 0x40 Error code ends with : 0xEF 7*h PPV output 8*h PGV output 9*h E5V output A*h E3V output B*h PTV output C*h MCH1R2-P1V output D*h 1R25-P1V output E*h 2R5-B2V output F*h TECRA M2 Maintenance Manual (960-468) 2-7