7. Alerts, Auto-Response and Logging 7.6.2 Serial Port Logging In Console Server mode, activity logs can be maintained of all serial port activity. To specify which serial ports are to have activities recorded and to what level data is to be logged: • Select Serial & Network: Serial Port. Edit the port to be logged. • Specify the Logging Level of for each port as: Level 0 Turns off logging for the selected port. Level 1 Logs all user connection events to the port. Level 2 Logs all data transferred to and from the port and all changes in hardware flow control status and all user connection events. Level 3 Logs all data transferred from the port and all changes in hardware flow control status and all user connection events. Level 4 Logs all data transferred to the port, all changes in hardware flow control status and all user connection events. • Click Apply Note: A cache of the most recent 8K of logged data per serial port is maintained locally (in addition to the logs, which are transmitted for remote/USB flash storage). To view the local cache of logged serial port data select Manage: Port Logs. 7.6.3 Network TCP and UDP Port Logging The console server supports optional logging of access to and communications with network-attached hosts. • For each host, when you set up the permitted services that are authorized to be used, you also must set up the level of logging that is to be maintained for each service. 148