ViewSonic VG930M Service Manual - Page 27

Firmware Update Procedure

Page 27 highlights

Firmware Update Procedure 17. 1 The monitor's firmware update for VG930 have two method. 1.1. Download the MCU IC by the fire machine. This procedure is finished in SMT . 1.2. ISP Method. When the monitor's BIOS isn't exist or firmware isn't final program, this method Is worked by ISP Cord with monitor 17.2.1 Equipment Needed - USB cable for print port *1 - VGA cable*1 - LPT cable (25pin)*1 - AC power cable*1 - ISP fire cord ( the fixture is made in TE ) for firmware upgrade*1 - Power adapter for firmware upgrade (this adapter is made in TE)*1 - A computer with WindowsXP - VG930 monitor ( no firmware) - a additional monitor for system display - ISP & ISP3.0 program 2. VG930 monitor upgrade firmware by ISP Cord. NOTE: The fixture for firmware upgrade provide two different method to fire. Please check you monitor's Main board, refer to MCU-RSIC type and choose the method. Below form appear the relation between the method and the MCU-RSIC type METHOD A B MCU MYSON OTHER ASIC M-STAR & NOVATEK REALTEK JUMPER PIN2-3 CLOSED PIN1-2 CLOSED ViewSonic Corporation Confidential - Do Not Copy VG930m-3_VA930m-1 24

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86

ViewSonic Corporation
Confidential - Do Not Copy
VG930m-3_VA930m-1
24
Firmware Update Procedure
17. 1 The monitor’s firmware update for VG930 have two method.
1.1. Download the MCU IC by the fire machine. This procedure is finished in SMT .
1.2. ISP Method. When the monitor’s BIOS isn’t exist or firmware isn’t final program, this method Is worked by
ISP Cord with monitor
17.2.1 Equipment Needed
- USB cable for print port *1
- VGA cable*1
- LPT cable (25pin)*1
- AC power cable*1
- ISP fire cord ( the fixture is made in TE ) for firmware upgrade*1
- Power adapter for firmware upgrade (this adapter is made in TE)*1
- A computer with WindowsXP
- VG930 monitor ( no firmware)
- a additional monitor for system display
- ISP & ISP3.0 program
2. VG930 monitor upgrade firmware by ISP Cord.
NOTE:
The fixture for firmware upgrade
provide two different method to fire. Please check you monitor’s
Main board, refer to MCU-RSIC type and choose the method.
Below form appear the relation between the method and the MCU-RSIC type
METHOD
MCU
ASIC
JUMPER
A
MYSON
M-STAR & NOVATEK
PIN2-3 CLOSED
B
OTHER
REALTEK
PIN1-2 CLOSED