Weber Summit Gold D LP Owner Manual - Page 48

Rotisserie Troubleshooting

Page 48 highlights

Rotisserie Troubleshooting Problem Burner does not light. Check Did you hold the burner control knob down and hold down for 20 seconds until after burner ignited? Is the igniter sparking? Cure Try to relight burner by holding burner control knob down and continue holding down until 20 seconds after burner has ignited. Replace battery in igniter button module. Reseat burner ring. Burner does not light or burner has a small flickering flame. The excess flow safety device, which is part of the grill to cylinder connection, may have activated. Too reset the excess flow safety device turn all burner control knobs and the cylinder valve OFF. Disconnect the regulator from the cylinder. Turn burner control knobs to HIGH. Wait at least 1 minute. Turn burner control knobs OFF. Reconnect the regulator to the cylinder. Turn cylinder valve on slowly. Refer to "Lighting Instructions" If problems cannot be corrected by using these methods, please contact the Customer Service Representative in your region using the contact information sheet provided with your manual. D-15

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52

D-15
Rotisserie Troubleshooting
Problem
Check
Cure
Burner does not light.
Did you hold the burner control
knob down and hold down for 20
seconds until after burner ignited?
Try to relight burner by holding
burner control knob down and
continue holding down until 20
seconds after burner has ignited.
Is the igniter sparking?
Replace battery in igniter button
module.
Reseat burner ring.
Burner does not light or burner
has a small flickering flame.
The excess flow safety device,
which is part of the grill to cylinder
connection, may have activated.
Too reset the excess flow safety
device turn all burner control knobs
and
the cylinder valve OFF.
Disconnect the regulator from the
cylinder. Turn burner control knobs
to HIGH. Wait at least 1 minute. Turn
burner control knobs OFF.
Reconnect the regulator to the
cylinder. Turn cylinder valve on
slowly. Refer to
Lighting
Instructions
If problems cannot be corrected by using these methods, please contact the Customer
Service Representative in your region using the contact information sheet provided with
your manual.