Weber Summit Gold D LP Owner Manual - Page 50
Replacing Main Burners
View all Weber Summit Gold D LP manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 50 highlights
Maintenance Replacing Main Burners 9. 1. Your Summit® gas grill must be OFF and cool. 2. Turn gas OFF at source. 3. Disconnect regulator. 4. Remove cooking grates. 5. Remove Smoker box. 6. Remove Flavorizer® bars. 7. To remove control panel refer to "Remove the control panel" under "Check for Gas Leaks." 8. Disconnect all ignition wires from the Ignition Module. Disconnect the Thermocouple from the IR Burner valve. -+ -+ a c ef bd a = Blue Tab with Black Wire b = Yellow Tab with Black Wire c = White Tab with Black Wire d = Solid White Wire e = Green Tab with Black Wire f = Solid Red Wire 10. Remove screws from the manifold assembly: (a) Locate the screws on both sides of the manifold frame. (b) Remove the screws from manifold frame. (a) (b) (a) (b) E-2