Electrical Shock Hazard Electrically ground dishwasher. Connect ground wire to green ground connector in terminal box. Do not use an extension cord. Failure to follow these instructions can result in death, fire, or electrical shock. 2 Direct Wire-Connect ground wire Wiring configuration Power supply wire: white black ground wire Terminal box wire: white black ground connector If needed, see website for animated representation of this step. Visit www.whirlpool.com/electrical under FAQ tab. 4 Direct Wire-Secure cable in conduit connector Ground wire Ground wire Washer Ground connector Form bare ground wire into a U-shaped hook. Wrap ground wire hook clockwise around ground connector screw and under the washer. Securely tighten ground connector. 3 Direct Wire-Connect remaining wires Tighten strain relief screws to secure cable. 5 Direct Wire-Reinstall terminal box cover Place wires inside terminal box. Insert tabs on left side of cover. Make sure wires are tucked inside box. Close cover ensuring wires are not pinched. Use ¹⁄₄" nut driver and previously removed screw to secure cover. NOTE: Do not pre-twist stranded wire. Twist on UL Listed/CSA Approved wire connector. Gently tug on wires to be sure both are secured. Connect wires black to black and white to white, using UL Listed/CSA Approved twist-on wire connectors (not included). 17

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40

17
Form bare ground wire into a U-shaped hook. Wrap ground wire
hook clockwise around ground connector screw and under the
washer. Securely tighten ground connector.
Electrical Shock Hazard
Electrically ground dishwasher.
Connect ground wire to green ground connector
in terminal box.
Do not use an extension cord.
Failure to follow these instructions can result in
death, fire, or electrical shock.
Ground
wire
Direct Wire
Connect
ground wire
2
Ground
wire
Washer
Ground
connector
Terminal box wire:
white
black
ground connector
Power supply wire:
white
black
ground wire
Wiring configuration
If needed, see website for animated representation
of this step. Visit
www.whirlpool.com/electrical
under FAQ
tab.
NOTE:
Do not pre-twist stranded wire. Twist on UL Listed/CSA
Approved wire connector. Gently tug on wires to be sure both
are secured.
Connect wires black to black and white to white, using UL
Listed/CSA Approved twist-on wire connectors (not included).
Direct Wire
Connect
remaining wires
3
Tighten strain relief screws to secure cable.
Direct Wire
Secure cable
in conduit connector
4
Place wires inside terminal box. Insert tabs on left side of cover.
Make sure wires are tucked inside box. Close cover ensuring
wires are not pinched. Use
¹⁄₄
" nut driver and previously
removed screw to secure cover.
Direct Wire
Reinstall
terminal box cover
5