Whirlpool GCEM2990TQ Installation Instructions - Page 10

Installation, Instructions- Gasdryer

Page 10 highlights

iNSTALLATIONiNSTRUCTiONS- GASDRYER ii!_,%,,__j?_ii_?Tf!,_i!i!,_i_!iiiii_ii:i_:,:i_li_:!!i(iii:ii_!_ NOTE: Slide dryer onto cardboard or hardboard before moving to avoid damaging floor covering. 1, Using two or more people, move dryer to desired installation location. 2, Take tape off front corners of dryer. Open dryer and remove the literature and parts packages. Wipe the interior of the drum thoroughly with a damp cloth. 3, Take two of the cardboard corners from the carton and place them on the floor in back of the dryer. Firmly grasp the body of the dryer and gently lay it on its back on the cardboard corners. 4, With one of the legs in hand, check the ridges for a diamond marking. That's how far the leg is supposed to go into the hole. 5, Start to screw the leveling legs into the holes by hand. (Use a small amount of liquid detergent to lubricate the screw threads so it is easier to turn the legs.) Use a 1-inch wrench or socket wrench to finish turning the legs until you reach the diamond mark. Now stand the dryer up. 6, Remove cardboard or hardboard from under dryer. 1, Using a 4" (10.2 cm) clamp, connect vent to exhaust outlet in dryer. If connecting to existing vent, make sure the vent is clean. The dryer vent must fit over the dryer exhaust outlet and inside the exhaust hood. Make sure the vent is secured to exhaust hood with a 4" (10.2 cm) clamp. 2, Move dryer into final position. Do not crush or kink vent. Make sure dryer is level 3, Check to be sure there are no kinks in the flexible gas line. With dryer in final position place level on top of the dryer, first side to side; then front to back. If the dryer is not leveI, adjust the legs of the dryer up or down until the dryer is level. Electrica_ Shock Hazard P_ug into a grounded 3 prong outlet, Do not remove ground prong, Do not use an adapter. Do not use an extension cord, Failure to follow these instructions can result in death, fire, or electrical shock, 1, Remove red cap from gas pipe. 2, Connect gas supply to dryer. Use pipe-joint compound resistant to the action of LR gas for gas connections. If flexible metal tubing is used, be certain there are no kinks. If necessary for service, open the toe panel. Use a putty knife to press on the toe panel lock located at the center top of the toe panel. Pull downward on the toe panel to open. Toe panel is hinged at the bottom. 3, Open the shutoff valve in the gas supply line. 4, Test all connections by brushing on an approved noncorrosive leak-detection solution. Bubbles will show a leak. Correct any leak found. 2, Plug into a grounded 3 prong outlet. 3, Check dryer operation (some accumulated time may be on the timer due to factory testing). Pull timer-set button left. (Operating time will accumulate per number of depressions and type of timing cam used.) Push START/RESTART button. Using a full heat cycle (not the air cycle), let the dryer run for at least five minutes. NOTE: Dryer door must be closed for dryer to operate. When door is open, dryer stops, but timer continues to run. To restart dryer, close door and push START/RESTART button. 4, If the burner does not ignite and you can feel no heat inside the dryer, shut off dryer for five minutes. Check that all supply valve controls are in "ON" position and that the electrical cord is plugged in. Repeat five-minute test. 5, If drying time is too long, make sure lint screen is clean. 10

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16

iNSTALLATION
iNSTRUCTiONS- GASDRYER
ii!_,%,,_j_i?
_?i_Tf!i!,_!
,_i!i_iiii_ii::_i_
ii:_,ili:!!i(iii:ii_!_
NOTE: Slide dryer onto cardboard
or hardboard
before moving to
avoid damaging
floor covering.
1,
Using two or more people, move dryer to desired installation
location.
2,
Take tape off front corners
of dryer. Open dryer and remove
the literature
and parts packages.
Wipe the interior of the
drum thoroughly
with a damp cloth.
3,
Take two of the cardboard
corners
from the carton and place
them on the floor in back of the dryer. Firmly grasp the body
of the dryer and gently lay it on its back on the cardboard
corners.
4,
With one of the legs in hand, check the ridges for a diamond
marking.
That's how far the leg is supposed
to go into the
hole.
5,
Start to screw the leveling
legs into the holes by hand. (Use a
small amount of liquid detergent
to lubricate the screw
threads so it is easier to turn the legs.) Use a 1-inch wrench or
socket
wrench to finish turning the legs until you reach the
diamond
mark.
Now stand the dryer up.
6,
Remove cardboard
or hardboard
from under dryer.
1,
Remove
red cap from gas pipe.
2,
Connect
gas supply
to dryer. Use pipe-joint
compound
resistant to the action of LR
gas for gas connections.
If
flexible metal tubing
is used, be certain there are no kinks.
If necessary for service, open the toe panel. Use a putty knife
to press on the toe panel lock located
at the center top of the
toe panel. Pull downward
on the toe panel to open. Toe panel
is hinged at the bottom.
3,
Open the shutoff
valve in the gas supply
line.
4,
Test all connections
by brushing
on an approved
noncorrosive
leak-detection
solution.
Bubbles
will show a leak. Correct
any
leak found.
1,
Using a 4" (10.2 cm) clamp,
connect
vent to exhaust
outlet in
dryer. If connecting
to existing
vent, make sure the vent is
clean. The dryer vent must fit over the dryer exhaust outlet
and inside the exhaust
hood.
Make sure the vent is secured to
exhaust
hood with a 4" (10.2 cm) clamp.
2,
Move dryer into final position.
Do not crush or kink vent. Make
sure dryer is level
3,
Check to be sure there are no kinks in the flexible gas line.
With dryer in final position
place level on top of the dryer, first
side to side; then front to back.
If the dryer is not leveI, adjust
the legs of the dryer up or down
until the dryer is level.
Electrica_
Shock
Hazard
P_ug into
a grounded
3 prong
outlet,
Do not remove
ground
prong,
Do not use an adapter.
Do not use an extension
cord,
Failure
to follow
these
instructions
can
result
in death,
fire, or electrical
shock,
2,
Plug into a grounded
3 prong outlet.
3,
Check dryer operation
(some accumulated
time may be on
the timer due to factory
testing).
Pull timer-set
button left. (Operating time will accumulate
per
number
of depressions
and type of timing cam used.) Push
START/RESTART button.
Using a full heat cycle (not the air
cycle), let the dryer run for at least five minutes.
NOTE: Dryer door must be closed
for dryer to operate. When
door is open, dryer stops, but timer continues to run. To
restart dryer, close door and push START/RESTART button.
4,
If the burner does not ignite and you can feel no heat inside
the dryer, shut off dryer for five minutes. Check that all supply
valve controls
are in "ON" position and that the electrical
cord
is plugged
in. Repeat five-minute
test.
5,
If drying time is too long, make sure lint screen is clean.
10