Yamaha 01V Owner's Manual - Page 284

SYSTEM EXCLUSIVE, MESSAGE Bulk Dump &amp, REQUEST, PARAMETER CHANGEtype 0x05:remote meter

Page 284 highlights

MIDI Data Format 285 PARAMETER CHANGE(type 0x05:remote meter) When the following request is received to enable transmission, the specified parameter data will be transmitted at 30 msec intervals for five seconds. If you want meter data to be transmitted continuously, you must continue transmitting requests less than five seconds apart. Reception When [Parameter Change RX] is ON and the [Rx CH] matches the Device Channel that is included in the SUB STATUS, this message is received. When [LOCAL OFF] is ON, the incoming meter data will be displayed. In other cases it will be ignored. Transmission When transmission is enabled by a request, this will be transmitted every 30msec on the [Rx CH] channel, for five seconds. Transmission will be disabled when the power is turned on, and when PORT settings have been modified. STATUS ID No. SUB STATUS GROUOP ID MODEL ID PARAM TYPE DATA EOX 11110000 F0 01000011 43 0001nnnn 1n 00111110 3e 00000100 04 00000101 05 0sgttttt tt 0mmmmmmm mm0 0mmmmmmm mm1 : : 11110111 F7 System Exclusive Message Manufacturer's ID No.(YAMAHA) n=0-15(Tx/Rx Channel No.1-16) MODEL ID Device code (01V) remote meter meter no.(s:special bit, g:gr bit) End Of Exclusive In the Meter no., bit 6 is the special bit, and bit 5 is the gr bit. When the Gr bit is on, the single byte gr will be added uniformly to the end of the data string. When the Special bit is on, the two bytes stLED L/R will be added uniformly to the end of the data string. When both are on, gr comes first, and stLED L/R come later. PARAMETER VALUE REQUEST(type 0x05:remote meter) This message is used to obtain meter data from the 01V. It is used in LOCAL OFF MODE to display the meter of the remote device, or to display the meter on the screen of a personal computer, etc. In order to obtain meter data, the meter whose data is required must be displayed in the LCD of the remote device. This means that before transmitting this request, you must first transmit the above-described "4.6.4.11 PARAMETER CHANGE (type 0x03:bit operation for controller(LCD-Fader mode))" to display the appropriate meter in the LCD screen of the remote device. Reception When [Parameter Change RX] is ON and the [Rx CH] matches the Device Channel included in SUB STATUS, this message will be received. When this message is received, Parameter Change (remote meter) messages will begin to be transmitted on the [Rx CH] channel. Transmission When [LOCAL OFF] is ON, transmit a meter data request for the currently displayed meter on the [Tx CH]. For each request, meter data will be transmitted for five seconds. If you want meter data continuously for longer than this, you will need to transmit requests at intervals of five seconds or less. When the 01V is in LOCAL OFF MODE, transmit requests at approximately one-second intervals. When [Parameter Change ECHO] is ON and the 01V itself did not receive this message, the message will be echoed. STATUS ID No. SUB STATUS GROUOP ID MODEL ID PARAM TYPE DATA EOX 11110000 F0 01000011 43 0011nnnn 3n 00111110 3e 00000100 04 00000101 05 0sgttttt tt 11110111 F7 System Exclusive Message Manufacturer's ID No.(YAMAHA) n=0-15(Tx/Rx Channel No.1-16) MODEL ID Device code (01V) remote meter meter no.(s:special bit, g:gr bit) End Of Exclusive Table of signal levels and codes Level code Level code Level code -72dB 0x1F -30dB 0x57 -9dB 0x72 -68dB 0x24 -27dB 0x5A -8dB 0x73 -64dB 0x29 -24dB 0x5F -7dB 0x75 -60dB 0x2F -21dB 0x62 -6dB 0x77 -56dB 0x33 -18dB 0x67 -5dB 0x78 -51dB 0x3A -16dB 0x69 -4dB 0x79 -48dB 0x3F -15dB 0x6A -3dB 0x7A -46dB 0x41 -14dB 0x6B -2dB 0x7B -42dB 0x47 -13dB 0x6D -1dB 0x7D -39dB 0x4A -12dB 0x6F 0dB 0x7E -36dB 0x4F -11dB 0x70 CLIP 0x7F -33dB 0x52 -10dB 0x71 5. SYSTEM EXCLUSIVE MESSAGE (Bulk Dump) & REQUEST These messages input and output the contents of various types of internal memory. The unique header identifies whether or not the data is for the 01V. The CHECK SUM is calculated by adding the data following the BYTE COUNT(LOW) until the data preceding the CHECK SUM, then inverting the bits (2's complement), and setting bit 7 to 0. CHECK SUM = ( -sum) & 0x7F Reception This is received if [Bulk RX] is ON and the [Rx CH] matches the Device Channel that is included in SUB STATUS. When a BULK DUMP is received, it will immediately be written into the specified memory. When a BULK DUMP REQUEST is received, a bulk dump will be transmitted immediately. Transmission In the [MIDI-BULK] page, this is transmitted on the [Tx CH] channel by key operations. In response to a Bulk Dump Request, a Bulk Dump Message is transmitted on the [Rx CH] channel. data name rx/tx function 'M' rx/tx Scene Memory & Request 'S' rx/tx Setup Memory & Request 'I' rx/tx Remote(Internal Parameter) Memory & Request 'L' rx/tx Remote(MMC) Memory & Request 'U' rx/tx Remote(User Define) Memory & Request 'C' rx/tx Control Change Assign Table & Request 'P' rx/tx Program Change Assign Table & Request 'Q' rx/tx Equalizer Library & Request 'Y' rx/tx Dynamics Library & Request 'E' rx/tx Effect Library & Request 01V-Owner's Manual

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260
  • 261
  • 262
  • 263
  • 264
  • 265
  • 266
  • 267
  • 268
  • 269
  • 270
  • 271
  • 272
  • 273
  • 274
  • 275
  • 276
  • 277
  • 278
  • 279
  • 280
  • 281
  • 282
  • 283
  • 284
  • 285
  • 286
  • 287
  • 288
  • 289
  • 290
  • 291
  • 292
  • 293
  • 294
  • 295
  • 296
  • 297
  • 298
  • 299
  • 300
  • 301
  • 302
  • 303

MIDI Data Format
285
01V—Owner’s Manual
PARAMETER CHANGE(type 0x05:remote meter)
When the following request is received to enable transmission, the
specified parameter data will be transmitted at 30 msec intervals for
five seconds. If you want meter data to be transmitted continuously,
you must continue transmitting requests less than five seconds apart.
Reception
When [Parameter Change RX] is ON and the [Rx CH] matches the
Device Channel that is included in the SUB STATUS, this message is
received.
When [LOCAL OFF] is ON, the incoming meter data will be dis-
played. In other cases it will be ignored.
Transmission
When transmission is enabled by a request, this will be transmitted
every 30msec on the [Rx CH] channel, for five seconds.
Transmission will be disabled when the power is turned on, and when
PORT settings have been modified.
In the Meter no., bit 6 is the special bit, and bit 5 is the gr bit.
When the Gr bit is on, the single byte gr will be added uniformly to
the end of the data string.
When the Special bit is on, the two bytes stLED L/R will be added uni-
formly to the end of the data string.
When both are on, gr comes first, and stLED L/R come later.
PARAMETER VALUE REQUEST(type 0x05:remote
meter)
This message is used to obtain meter data from the 01V. It is used in
LOCAL OFF MODE to display the meter of the remote device, or to
display the meter on the screen of a personal computer, etc.
In order to obtain meter data, the meter whose data is required must
be displayed in the LCD of the remote device. This means that before
transmitting this request, you must first transmit the
above-described "4.6.4.11 PARAMETER CHANGE (type 0x03:bit
operation for controller(LCD-Fader mode))" to display the appro-
priate meter in the LCD screen of the remote device.
Reception
When [Parameter Change RX] is ON and the [Rx CH] matches the
Device Channel included in SUB STATUS, this message will be
received.
When this message is received, Parameter Change (remote meter)
messages will begin to be transmitted on the [Rx CH] channel.
Transmission
When [LOCAL OFF] is ON, transmit a meter data request for the
currently displayed meter on the [Tx CH]. For each request, meter
data will be transmitted for five seconds. If you want meter data con-
tinuously for longer than this, you will need to transmit requests at
intervals of five seconds or less. When the 01V is in LOCAL OFF
MODE, transmit requests at approximately one-second intervals.
When [Parameter Change ECHO] is ON and the 01V itself did not
receive this message, the message will be echoed.
Table of signal levels and codes
5. SYSTEM EXCLUSIVE
MESSAGE (Bulk Dump) &
REQUEST
These messages input and output the contents of various types of
internal memory.
The unique header identifies whether or not the data is for the 01V.
The CHECK SUM is calculated by adding the data following the
BYTE COUNT(LOW) until the data preceding the CHECK SUM,
then inverting the bits (2's complement), and setting bit 7 to 0.
CHECK SUM = ( -sum) & 0x7F
Reception
This is received if [Bulk RX] is ON and the [Rx CH] matches the
Device Channel that is included in SUB STATUS.
When a BULK DUMP is received, it will immediately be written into
the specified memory.
When a BULK DUMP REQUEST is received, a bulk dump will be
transmitted immediately.
Transmission
In the [MIDI-BULK] page, this is transmitted on the [Tx CH] chan-
nel by key operations.
In response to a Bulk Dump Request, a Bulk Dump Message is trans-
mitted on the [Rx CH] channel.
STATUS
11110000 F0
System Exclusive Message
ID No.
01000011 43
Manufacturer's ID No.(YAMAHA)
SUB STATUS
0001nnnn 1n
n=0-15(Tx/Rx Channel No.1-16)
GROUOP ID
00111110 3e
MODEL ID
MODEL ID
00000100 04
Device code (01V)
PARAM TYPE
00000101 05
remote meter
DATA
0sgttttt tt
meter no.(s:special bit, g:gr bit)
0mmmmmmm mm0
0mmmmmmm mm1
:
:
EOX
11110111 F7
End Of Exclusive
STATUS
11110000 F0
System Exclusive Message
ID No.
01000011 43
Manufacturer's ID No.(YAMAHA)
SUB STATUS
0011nnnn 3n
n=0-15(Tx/Rx Channel No.1-16)
GROUOP ID
00111110 3e
MODEL ID
MODEL ID
00000100 04
Device code (01V)
PARAM TYPE
00000101 05
remote meter
DATA
0sgttttt tt
meter no.(s:special bit, g:gr bit)
EOX
11110111 F7
End Of Exclusive
Level
code
Level
code
Level
code
-------------------------------------------------------------------------------------
-72dB
0x1F
-30dB
0x57
-9dB
0x72
-68dB
0x24
-27dB
0x5A
-8dB
0x73
-64dB
0x29
-24dB
0x5F
-7dB
0x75
-60dB
0x2F
-21dB
0x62
-6dB
0x77
-56dB
0x33
-18dB
0x67
-5dB
0x78
-51dB
0x3A
-16dB
0x69
-4dB
0x79
-48dB
0x3F
-15dB
0x6A
-3dB
0x7A
-46dB
0x41
-14dB
0x6B
-2dB
0x7B
-42dB
0x47
-13dB
0x6D
-1dB
0x7D
-39dB
0x4A
-12dB
0x6F
0dB
0x7E
-36dB
0x4F
-11dB
0x70
CLIP
0x7F
-33dB
0x52
-10dB
0x71
data name
rx/tx
function
------------------------------------------------------------------------------------------------------
'M'
rx/tx
Scene Memory & Request
'S'
rx/tx
Setup Memory & Request
'I'
rx/tx
Remote(Internal Parameter) Memory & Request
'L'
rx/tx
Remote(MMC) Memory & Request
'U'
rx/tx
Remote(User Define) Memory & Request
'C'
rx/tx
Control Change Assign Table & Request
'P'
rx/tx
Program Change Assign Table & Request
'Q'
rx/tx
Equalizer Library & Request
'Y'
rx/tx
Dynamics Library & Request
'E'
rx/tx
Effect Library & Request