Yamaha EF2000iS Owners Manual - Page 12

CONTROL FUNCTION, DC protector - won t start

Page 12 highlights

AE00101 CONTROL FUNCTION 2 1 AE00121 Engine switch The engine switch controls the ignition system. 7DK-018 1 7 "ON" Ignition circuit is switched on. The engine can be started. 2 5 "STOP" Ignition circuit is switched off. The engine will not run. AE00111 Oil warning light (Red) When the oil level falls below the lower level, the oil warning light comes on and then the engine stops automatically. Unless you refill with oil, the engine will not start again. TIP If the engine stalls or does not start, turn the engine switch to "ON" and then pull the recoil starter. If the oil warning light flickers for a few seconds, the engine oil is insufficient. Add oil and restart. 700-115 DC protector The DC protector turns off 2 automatically when electric device being connected to the generator is operating and current above the rated flows. To use this equipment again, turn on the DC protector by pressing its button to "ON" 1. 21 7DK-052 1 "ON" Direct current is output. (This is the default position.) 2 "OFF" Direct current is not output. -7-

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48

7
1
2
7DK-018
700-115
AE00111
Oil warning light (Red)
When the oil level falls below the lower level, the oil
warning light comes on and then the engine stops auto-
matically. Unless you refill with oil, the engine will not
start again.
TIP
If the engine stalls or does not start, turn the engine
switch to
ON
and then pull the recoil starter. If the oil
warning light flickers for a few seconds, the engine oil is
insufficient. Add oil and restart.
AE00101
CONTROL FUNCTION
AE00121
Engine switch
The engine switch controls the ignition system.
1
7
ON
Ignition circuit is switched on.
The engine can be started.
2
5
STOP
Ignition circuit is switched off.
The engine will not run.
DC protector
The DC protector turns off
2
automatically when elec-
tric device being connected to the generator is operat-
ing and current above the rated flows.To use this equip-
ment again, turn on the DC protector by pressing its
button to
ON
1
.
1
2
7DK-052
1
ON
Direct current is output. (This is the default position.)
2
OFF
Direct current is not output.